IDC Pro 255 Installation Manual
Publication Number: 621058578INS
- 38 -
© 2016-2018, Cornelius Inc.
NOTE: Contact your local syrup or beverage equipment distributor for additional information and trouble-
shooting of beverage system.
Carbonator tank overfills,
overflows through relief
valve, and pump shuts off
after 5 minutes.
A. Poor electrical connections between car-
bonator tank and main control board.
B. Broken wires between carbonator tank and
main control board.
C. Defective liquid level probes.
A. Check connections at carbonator tank and
at connector J4 on the main control board
B. Replace wire harness.
C. Replace both liquid level probes.
Table 18
Symptom
Cause
Remedy