IDC Pro 255 Installation Manual
Publication Number: 621058578INS
- 24 -
© 2016-2018, Cornelius Inc.
Figure 8.
Cleaning Interior Surfaces
As part of the initial cleaning procedures, clean and sanitize the ice hopper by performing the procedure in Table 13.
CAUTION:
!
When pouring liquid into the hopper, do not exceed the rate of 1/2 gallon per minute. Pouring liquid into the hopper
faster than the recommended rate could result in an overflow situation which may result in personal injury or damage
to the equipment.
9
Turn the flow adjustment valve a 1/4 of a turn at a time and recheck the flow. To increase the flow, turn the knob
clockwise. To decrease, turn counter- clockwise.
10
Test the valve and adjust until a consistent ratio is delivered two consecutive times.
11
Select CW2 and press Pour to dispense 3.0 oz (90 ml.)
12
Perform Steps 8 through 10 for the CW2 valve.
13
Select PW1 and press Pour to dispense 7.0 oz (210 ml.).
14
Perform Steps 8 through 10 for the PW1 valve.
15
Select PW2 and press Pour to dispense 3.0 oz (90 ml.)
16
Perform Steps 8 through 10 for the PW2 valve.
17
Select CW3 and Pour to dispense 7.0 oz (210ml.).
18
Perform Steps 8 through 10 for the CW3 valve.
19
Select CW4 and press Pour to dispense 3.0 oz (90 ml.)
20
Perform Steps 8 through 10 for the CW4 valve.
21
Select PW3 and press Pour to dispense 7.0 oz (210 ml.).
22
Perform Steps 8 through 10 for the PW3 valve.
23
Select PW4 and press Pour to dispense 3.0 oz (90 ml.)
24
Perform Steps 8 through 10 for the PW4 valve.
25
Place a graduated cylinder under the valve.
26
Select S1 and press Pour to dispense follow manufacturer’s specs for proper ratio.
27
If the rate is not correct, perform Steps 8 through 10 for the S1 valve.
28
Repeat Steps 26 and 27 for S2 through S7 and A1 through A3.
29
Repeat Steps 26 through 27 for S8 through S14 and A4 through A6.
30
When the flow rate process is complete, select the Back button to return to the Unit Setup screen.
31
Press the Back button on the Unit Setup screen to return to the Service UI screen.
32
Press the Log Out button to return to normal operation.
Water Valves
(White)
Syrup Valves
(Black)
Flavor Shots
(Purple)
(Same layout as opposite side)
Table 12.
Step
Action