IDC Pro 255 Installation Manual
© 2016-2018, Cornelius Inc.
- 23 -
Publication Number: 621058578INS
2
Input the proper password for your access level
(technician) and press Enter.
1
2
3
4
5
6
7
8
9
0
Enter
<
3
Press the Unit Setup button.
Unit Setup
4
Select the Brix setup screen.
5
All instructions and volumes below are based
on the pour rate of 3oz/sec.
NOTE: When selecting a valve, it will
activate for a pre-programmed 4
second dispense time.
6
Place a Ratio cup under the valve.
7
Select the CW1 button and press Pour to dispense 7.0 oz (210 ml.).
8
If the flow rate is not correct, adjust the proper valve to the desired flow. Refer to Figure 8. for valve locations.
Table 12.
Step
Action
Содержание IDC PRO 255