Technical Support Manual – 05/2018 Rel. 2.1.3
Page 21
DIA
Diameter sensor calibration
ATTENTION: these instructions are valid only for the diameter sensor with accelerator board.
Description
1
Enter the SERVICE mode by pressing [F+P3]
.
2
Press [P1]
to enter the Sensors
Calibration Menu.
3
Browse the list of the menus with [P4]
or [P5]
until the option
required is displayed.
4
Press [P1]
to confirm the
DIAMATER sensor calibration program.
Position the distance/diameter sensor as
shown.
The left display will report the output
voltage.
Example
5
The voltage must be between:
0.99 e 1.13.
Confirm the new value by pressing [P2]
.
If the value is not within the above range,
proceed with adjusting.
Example