UT
Handbook for Use and Maitenance – 50000 WB-80-87-95
Edition
01/11
Revisione
00
33
50000WB_e111_E.doc
DANGER OF OVERTURNING
In case of a failure of the electric
system, that can not be repaired
on site, it is possible to operate the
crane, only in order to lower the
load and fold the crane, by acting
on an electric valve located behind
the operator’s seat (picture 29
)after
bracking
the
Cormach
sealing, keep pushing the button of
the electric valve, shown in the
picture, and operate in such a way
that bring the crane back into
safety conditions.
During emergency operation, keep an eye on the load indicator so that
the crane is not overloaded and only perform manoeuvres that bring the load
towards the slewing axis.
The system must be repaired before operating the crane again and the
button on the solenoid must be re-sealed with a lead seal at a workshop
authorised by Cormach.
WARRANTY ON CRANE IS CANCELLED, THE MANUFACTURER DECLAINS
ALL RESPONSABILITIES FOR DAMAGES TO PERSONS, IN CASE THE CRANE IS
USED WITHOUT WORKING SAFETY DEVICES.
Picture 29