![Copley Controls Xenus PLUS Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/copley-controls/xenus-plus/xenus-plus_manual_2666137030.webp)
Qty
Description
1
Heatsink, standard,
800-1782
1
Thermal pad, 4x4 in.
1
Kit, Heatsink Hardware,
800-1782
4
Washer, flat, #8
4
Screw, PAN, SEMS, #8-32 x 1/2 in
1
2
3
.336[8.54]
8X
.098[2.50]
.395[10.04]
137.2
5.40
22.1
.87
2X
42.01
1.654
2X
50.83
2.001
2X
2X
42.01
1.654
M3X0.5 - 6H
2.41 61.1
.160 4.06
3.92 99.6
32
.001
4X .50 12.7
4X #8-32 UNC
8.33
.328
9.9
.39
3.9 99.6
226.57
2X 8.920
234.7
9.24
4X .50 12.7
.24 6.1
10-32 UNF THRU
.159[4] THRU
.691 17.6
4.06
2X .160
76
2X 2.991
2X 1.17 29.7
2X
1.79 45.5
THERMAL PAD PLACEMENT ZONE
.02 0.5
PART NUMBER
0.4 in
10 mm
1.8 in
45.5 mm
XE2 front panel
on this side
Copley Controls, 20 Dan Road, Canton, MA 02021, USA
Tel: 781-828-8090
Fax: 781-828-6547
Tech Support: E-mail: [email protected], Web:
http://www.copleycontrols.com
Page 30 of 32
RoHS
Xenus
PLUS
2-Axis
EtherCAT
800-1782
HEATSINK KIT PART LIST
HE2-HK HEATSINK KIT INSTALLATION
• Standard heatsink for Xenus Plus model 800-1782
• Complete kit for user installation of the heatsink
HEATSINK
(Mounting hardware not
shown)
DESCRIPTION
The XE2-HK is a kit containing a heatsink and
mounting
hardware for field installation of a standard heatsink onto
Xenus Plus 800-1782 model servo drive.
To order an 800-1782 drive with heatsink fitted at the
factory, add “-H” to the number.
INSTALLATION
1) Place the heatsink fins-down on a work surface.
Orient the heatsink so that the edge with part number
is away from you. The hole for the 800-1782 grounding
lug should be to your left.
2) Remove the clear protective film from the thermal
material and discard it. Place the thermal material onto
the heatsink in the placement area which is marked with
four white “L”. Apply light pressure to ensure that the
thermal material is flat.
3) Peel the white protective layer away from the thermal
material. Do this slowly from one corner so as not to lift
the thermal material from the heatsink.
4) Align the
800-1782 as shown and lower onto the
heatsink. If needed to adjust the position, lift it away
from the thermal material and lower onto the heatsink
again.
5) Install the four mounting screws with flat washers
and tighten evenly. Torque to 17.8 lb-in (2.0 Nm)
maximum.
XE2 grounding
lug hole
Thermal material
placement area
Thermal material
Note: If alignment markings are not
on heatsink, use these dimensions to
place the pad