Installation Instructions – Galleon II Area Site and Flood 

2

Cooper Lighting Solutions    

   

IB500157EN

 

    

 Installation instructions

Standard Pole Mount Arm (Fig. 1)

Tools Required:

 

Ratchet with shallow 3/4” socket

 

#2 Phillips head screwdriver

1.  Ensure the pole is drilled for pattern “N” and remove 

the pole top cap.

2.  Loosen (2) #8 screws to remove the access cover from 

the arm. Rotate down, sliding the cover forward to 

disengage from the rear slots.

3.  If applicable, install round pole adapter between 

luminaire and round pole. For square poles, this is not 

required.

4.  Thread (2) 1/2"-13 fasteners through the arm (and 

adapter, if present), pole, and into the nut plate. Hand-

tighten, ensuring the fixture is properly aligned. 

5.  Tighten both bolts to 40 ft-lbs. (54 N-m).

6.  Route the supply leads into the arm, through the center 

opening of the nut plate, pole and arm.

7.  Attach the supply side ground wire to the ground 

terminal connector (green wires).

8.  Connect the supply side line voltage wire to the fixture 

side line voltage terminal connector (black wires).

9.  Connect the supply side neutral wire to the fixture side 

neutral wire terminal connector (white wires).

10.  Insert the access cover by inserting the tabs into the 

rear arm slots and close the cover. Tighten the (2) #8 

screws and torque to 12-14 in-lbs.

11.  Replace pole top cap.

Standard Pole Mount Arm with Quick Mount Adapter 

(QM) (Fig. 2)

Tools Required:

 

Ratchet with 9/16” and 3/4” sockets

 

#2 Phillips head screwdriver

1.  Ensure the pole is drilled for pattern “N” and remove 

the pole top cap.

2.  Loosen (2) #8 screws to remove the access cover from 

the arm. Rotate down, sliding the cover forward to 

disengage from the rear slots.

3.  Thread (1) 1/2"-13 fastener through the top hole of the 

quick mount adapter bracket, through the top hole on 

the pole, and into the nut plate. Hand-tighten. Insert the 

lower ½” bolt a few turns to ensure alignment. Tighten 

the upper bolt to adapter bracket and pole to 40 ft-lbs. 

(54 N-m), ensuring the fixture is square to the pole and 

level, and remove the lower bolt.

4.  Position luminaire over adapter bracket, allowing the 

arm to engage the bracket to temporarily secure it. 

Reinstall the lower 1/2" bolt and hand-tighten. Install the 

3/8” fastener through the top of the adapter bracket 

into the luminaire arm. Tighten the 1/2" lower bolt to 40 

ft-lbs. (54 N-m.) Tighten the 3/8” fastener to 20 ft-lbs. 

(27 N-m.)

5.  Route the supply leads into the arm, through the center 

opening of the nut plate, pole and arm.

6.  Attach the supply side ground wire to the ground 

terminal connector (green wires).

7.  Connect the supply side line voltage wire to the fixture 

side line voltage terminal connector (black wires).

8.  Connect the supply side neutral wire to the fixture side 

neutral wire terminal connector (white wires).

9.  Insert the access cover by inserting the tabs into the 

rear arm slots and close the cover. Tighten the (2) #8 

screws and torque to 12-14 in-lbs.

10.  Replace pole top cap. 

Figure 1.   

Figure 2.   

Nut Plate

QM Arm

QM Bracket

3/8-16 Fastener 

2X #8 Fastener

2X - 1/2-13 Fastener

Access Cover

Access Door

4 SQ, 6 SQ & 9 SQ Housing

Nut Plate

Round Pole Adapter

Standard Arm

4 SQ, 6 SQ or 9 SQ 

Housing

Luminaire Access Door

2X - 1/2-13 Fastener 

2X #8 Fastener

Access Cover

ote: 

N

This lighting fixture has been shipped complete with one of several mounting options. Please follow the installation 

instructions specific to the catalog part that you ordered.

Содержание Galleon II

Страница 1: ...ure to rain dust or other environmental conditions prior to installation and insertion of photo control or shorting cap if so equipped Best results will be obtained if installed and maintained accordi...

Страница 2: ...wn sliding the cover forward to disengage from the rear slots 3 Thread 1 1 2 13 fastener through the top hole of the quick mount adapter bracket through the top hole on the pole and into the nut plate...

Страница 3: ...late Center Wire Way Round Pole Adapter 2X 1 2 13 Flange Bolt 2X Adjustment Bolt Do Not Remove Access Cover 3X 8 Screw Washer Plate Ensure B Arrow Is Facing Down Figure 3 Wall Mount Fixed WM Fig 4 Too...

Страница 4: ...to remove the access cover from the arm Set aside for installation 2 Align the center holes in the decorative wall plate to the fixture arm Install the washer plate and the 2 13 fasteners and hand ti...

Страница 5: ...crews then tighten the upper angled set screws to 20 ft lbs Install 3 hex nuts to the lower set screws and tighten both the 3 set screws and 3 nuts to 20 ft lbs 5 Inside the slipfitter arm connect sup...

Страница 6: ...lt to 20 ft lbs 27 N m 6 Route the fixture leads through the center opening of the nut plate pole and arm into the arm cavity 7 Attach the supply side ground wire to the ground terminal connector gree...

Страница 7: ...ion lectrique est HORS TENSION avant de commencer l installation ou de tenter d en faire l entretien Mettez l alimentation lectrique hors tension depuis le fusible ou le disjoncteur Risque d incendie...

Страница 8: ...19 16 po et 1 9 cm 3 4 po Tournevis pointe cruciforme n 2 1 Assurez vous que le poteau est perc pour un motif de type N et retirez le couvercle sup rieur du poteau 2 Desserrez les deux 2 vis n 8 pour...

Страница 9: ...blanc du luminaire c Le fil de tension provenant de l alimentation avec le fil noir du luminaire 9 Desserrez les deux 2 boulons embase M20x1 5 3 8 po 16 situ s dans les fentes pour r gler les angles d...

Страница 10: ...et la fl che soient orient s vers le bas 3 Serrez les deux 2 fixations M14x2 1 2 po 13 un couple de 54 Nm 40 pi lb Mettez le luminaire de c t 4 Faites passer les fils d alimentation de la bo te de jon...

Страница 11: ...M10x1 5 3 8 16 5X crous embase Poteau du client CROSSE Adaptateur d embo tement r glable Fig 7 et 8 Outils requis Cl rochet avec douille de 1 9 cm 9 16 po Cl hexagonale de 0 5 cm 1 4 po Cl de 1 9 cm 3...

Страница 12: ...rer pour assurer l alignement tout en serrant le support de montage sup rieur Serrez le boulon embase sup rieur au support du bras et au poteau un couple de 54 Nm 40 pi lb 4 Retirez la fixation inf ri...

Страница 13: ...u et toutes les remarques applicables Commutateur deux niveaux d intensit selon l quipement En cas de commutation deux niveaux d intensit chaque fil d alimentation du luminaire comportera une tiquette...

Страница 14: ...nstalaci n o intentar realizar cualquier tipo de mantenimiento Desconecte la alimentaci n el ctrica en el fusible o cortacircuitos Riesgo de incendio consulte la etiqueta del producto para conocer los...

Страница 15: ...del poste 2 Afloje los 2 tornillos n 8 para retirar la cubierta de acceso del brazo Gire hacia abajo deslizando la cubierta hacia adelante para que se suelte de las ranuras traseras 3 Enrosque 1 suje...

Страница 16: ...voltaje de l nea del lado de la alimentaci n al terminal negro de la luminaria 9 Afloje los 2 pernos de 3 8 16 ubicados en las ranuras para hacer ajustes de ngulo a la luminaria Una vez realizados es...

Страница 17: ...a B y la flecha miren hacia abajo 3 Apriete los 2 tornillos de 1 2 13 a 40 pies lb 54 Nm Deje a un lado la unidad de la luminaria 4 Tienda los cables de alimentaci n desde la caja de derivaci n a trav...

Страница 18: ...da ar los cables dentro del brazo del m stil Este orificio se puede perforar previamente para evitar da os en los cables 7 Instale el perno pasante de 3 8 16 x 4 5 y apriete a 14 pies lb 18 Nm 1 aran...

Страница 19: ...las ranuras delanteras 3 Instale y sostenga la placa de tuerca provista dentro del poste Instale 1 sujetador de 1 2 13 a trav s del adaptador el poste y en la placa de tuerca y aj stelo a mano Inserte...

Страница 20: ...si est provisto Para contar con un interruptor de doble nivel los cables de entrada a la luminaria deber n etiquetarse por separado para indicar las preferencias de regulaci n seg n corresponda defin...

Страница 21: ...ent generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of th...

Отзывы: