28
SPECIFICATIONS
Appendix A is the location for product performance information and electrical
specifications for the
1000W and 1800W Cooper Bussmann Inverter
.
Important:
Specs are subject to changes without notice.
Technical Specifications:
Input
voltages
Low
Setting
Mid Setting
High Setting
Nominal DC Input
12.5VDC
13.0VDC
13.0VDC
Input voltage operating
range
10.5 – 16.0VDC
11.8 – 16.0VDC
12.2 – 16.0VDC
No load input current
(inverter on)
Input voltage 11.5VDC and greater < 0.9a DC
Input voltage less than 11.5VDC < 1.5a DC
No load input current
(inverter off)
< 1.0mA (Inverter button off and no utility power connection)
All DC Voltage tole/‐ 0.3VDC
AC
Outputs
1000W
1800W
Continuous output power 1000W (8.3a)
1800W (15a)
Surge output power (5
seconds)
1200W
2000W
Surge output power
2000W (200ms)
3600W (300ms)
Operating Temperature
Range
0C to +50C
0C to +50C
THD (Resistive Load)
5% maximum, 2.5% typical
5% maximum, 2.5% typical
Output power rated at 25⁰C, continuous power de‐rated linearly to 70% at 50⁰C
AC
Transfer
AC input transfer from
95 VAC