background image

Revised: 02/12/2015 

 

2/12/2015 

27

 
WARRANTY 

 
DESIGNATION OF WARRANTOR.  This warranty is extended by Shamic Sheetmetal (Aust) 
Pty. Ltd with respect to Coonara gas heaters.  
PRODUCT.  This Coonara Gas heater is comprised of the heater proper (including components 
and  firebox),  fan  assembly,  speed  control  switch,  electrical  components,  gas  valves,  seals  and 
moving  parts.    Except  where  specifically  excluded  from  coverage  hereunder,  this  warranty 
covers all components designed. 
See exclusions and qualifications below for further information on product coverage. 
WARRANTY: 

1)

 

Shamic Sheetmetal (Aust) Pty. Ltd, warrants the firebox and the heat exchanger to be free 
of  defects  in  materials  and  workmanship  of  a  period  of  five  (5)  years  from  the  date  of 
purchase. 

2)

 

Shamic Sheetmetal (Aust.) Pty.Ltd., warrants that all other components of the unit to be 
free  of  defects  in  material  and  workmanship  for  a  period  of  two  (2)  years  from  date  of 
purchase, excluding door glass and decorative logs.  

3)

 

If this Coonara heater is found to be defective in material or workmanship Shamic will 
repair  or  replace  such  defects  in  the  Coonara  heater  at  Shamic’s  option  in  accordance 
with Coonara’s warranty policy during the period on this warranty. If the defect is found 
not  to  meet  the  Consumer  Guarantee  requirements  and  constitutes  a  major  failure,  the 
purchaser may be able to choose to repair or replace the defective heater or part or obtain 
a refund. 

4)

 

Exclusions and qualifications.  This warranty is  subject to the following  exclusions and 
qualifications. 

a)

 

This  warranty  extends  only  to  the  original  consumer  purchaser,  who  has 
purchased the heater from an authorised Coonara dealer. 

b)

 

This warranty does not apply to, and Coonara assumes no responsibility for any 
damages  that  result  due  to,  installation  or  operation  of  the  heater  not  in 
accordance with both the installation and operation instructions furnished with the 
unit. 

c)

 

This warranty does not apply to any heater which has been modified or damaged 
in shipping or by improper handling, improper operation, abuse, misuse, accident 
or unworkmanlike repairs. 

d)

 

Shamic  Sheetmetal  (Aust.)  Pty.Ltd.  does  not  warrant  the  structural  performance 
of  the  heater  when  fuel  products  other  than  the  specified  gas  fuels  are  used.  
Flammable liquid fuels are explosive and should never be used in this product. 

e)

 

Shamic Sheetmetal (Aust.) Pty.Ltd. expressly excludes any liability hereunder for 
defects or damage caused by the installation or of any components not expressly 
authorised  and  approved  by  Shamic.        Shamic  further  assumes  no  liability  for 
defects  or  damage  caused  by  any  modification  not  expressly  authorised  and 
approved by Shamic.  Unauthorised components or modifications could create  a 
fire hazard by altering the safety design of the heater. 

f)

 

Building Codes.  Since building code requirements vary, users should determine 
in advance whether there are any building code restrictions on the installation or 
use of the heater.  Shamic makes no representation of warranty regarding building 
code compliance and shall not be responsible for compliance therewith. 

g)

 

Shamic will only accept claims under this warranty in strict accordance with the 
conditions set out below. 

5)

 

Shamic Sheetmetal (Aust.) Pty.Ltd. shall not be liable for any breakages of glass and log 
components,  transit  damage  or,  where  it  can  be  shown  that  the  consumer  guarantee 
obligations as the manufacturer have been met, for any claim by any person for incidental 
or  consequential  damages  caused  by  defects  in  the  Coonara  heater.    Whether  such 
damage occurs or is discovered before or after replacement or repair, and whether or not 

Содержание Royal Classic

Страница 1: ...r of Heater ____________ Model ___________________ Serial Number of Heater ____________ Model ________________ Royal Slimline Classic Freestanding Gas Heaters ARE AUSTRALIAN OWNED AND MANUFACTURED BY...

Страница 2: ...ilt models must be placed on 6mm AC sheeting to prevent unit from rattling Heater must be checked for scratches or dents prior to installation All glass must be fitted with a screw driver not a drill...

Страница 3: ...TY FEATURES 7 INSTALLATION INSTRUCTIONS 8 15 DIMENSIONS INBUILT MODELS 16 17 DIMENSIONS FREESTANDING MODEL 18 19 PRESSURE ADJUSTMENTS 20 WIRING DIAGRAM PRESSURE SWITCH 21 BURNER REMOVAL 22 LOG SET 23...

Страница 4: ...YTH VIC 3136 To be installed by a Coonara authorised technician in accordance with installation instructions provided with the appliance Electrical Conform to AS3100 240v 50Hz 120Watts Max Air Pressur...

Страница 5: ...aged it must be replaced with an original Coonara part obtainable from your authorized dealer THE SAFETY GUARD AROUND THE GLASS DOOR IS FITTED TO THIS APPLIANCE TO REDUCE THE RISK OF FIRE OR INJURY FR...

Страница 6: ...before automatically going to the higher flame setting 3 The fan will not start until the heater has reached the minimum operating temperature 4 During first time firing of this appliance an odour may...

Страница 7: ...Pre purge Before heater ignition this operation is done to evacuate any remains of gas or flue products from inside the firebox that could be the cause of a mishap Automatic Shut off Should the flame...

Страница 8: ...connection must be removed by using a Tin Snip or similar tool See page 12 SERVICE INSTRUCTIONS INBUILT To access flue fan the over temp switch and the thermistor the heater needs to be removed To ac...

Страница 9: ...ed both flexible pipes down the flue cavity 3 Fix flue terminal securely to top of the flue cavity and seal to prevent water entry Seal with Hi temperature waterproof silicon sealant prior to cementin...

Страница 10: ...r from the pallet 3 Position heater locate and connect flue pipes to unit Connect gas to the flexible connection line and check pressure coming in Minimum pressure required NAT GAS 1 1 High and low se...

Страница 11: ...ry Cut out the outer brickwork 4 Fit the outer weather cover over the exposed heater body and screw to the outer wall Also use a silicon sealant 5 Feed the gas line through the hole located at the low...

Страница 12: ...Revised 02 12 2015 2 12 2015 12...

Страница 13: ...Revised 02 12 2015 2 12 2015 13...

Страница 14: ...Revised 02 12 2015 2 12 2015 14 INBUILT INSTALLATION...

Страница 15: ...2 12 2015 2 12 2015 15 INBUILT REAR FLUE INSTALLATION WITH OPTIONAL OFFSET FLUE BOX INBUILT FREESTANDING The Offset Flue Box is used only when wall flue penetration has less than 300mm high from outsi...

Страница 16: ...Revised 02 12 2015 2 12 2015 16...

Страница 17: ...Revised 02 12 2015 2 12 2015 17...

Страница 18: ...Revised 02 12 2015 2 12 2015 18...

Страница 19: ...Revised 02 12 2015 2 12 2015 19 SIDE VIEW REAR VIEW FRONT VIEW GRANGE ROYAL FREESTANDING 2 APPLIANCE DIMENSIONS...

Страница 20: ...and adjusted and should not need to be re adjusted during installation Gas pressures still need to be checked to the pressures shown on Page 4 of this manual But there will be some situations where so...

Страница 21: ...Revised 02 12 2015 2 12 2015 21 WIRING DIAGRAM FOR THERMOSTAT Sit Gear Tray PRESSURE SWITCH...

Страница 22: ...rew in the lower centre of the heater that hold the Fascia in place Then lift and pull the fascia towards you This will unclip the two hanging hooks inbuilt only 2 Undo the two self taper screws below...

Страница 23: ...015 23 COONARA ROYAL SLIMLINE CLASSIC LOG SET LOCATION DETAILS All logs have self locating points moulded into them This allows for accurate positioning of logs DO NOT INSTALL LOG LIKE THIS STEP 1 Fix...

Страница 24: ...Revised 02 12 2015 2 12 2015 24 STEP 2 STEP 3 STEP 4...

Страница 25: ...Revised 02 12 2015 2 12 2015 25 STEP 5 STEP 6 LOG SET FRONT VIEW...

Страница 26: ...sold you the heater 5 Advise them of the specific problem 6 Provide the details that your retailer requests to complete a Warranty Claim Form This must include the heater model serial number and insta...

Страница 27: ...no responsibility for any damages that result due to installation or operation of the heater not in accordance with both the installation and operation instructions furnished with the unit c This war...

Страница 28: ...laim under this warranty you must provide proof of purchase On purchase of the heater despatch your warranty card to Shamic Sheetmetal Aust Pty Ltd 9 Your authorised dealer must be notified of any def...

Страница 29: ...rating Insufficient time allowed Loose wiring Fan not located correctly Fan blocked Fan has a delayed start and will not start until unit warms up Check wiring Install fan in correct location Remove a...

Страница 30: ...Overall depth 450 mm Packed Weight 90 kg Firebox Casing Height 600 mm Width 705 mm Depth from rear of fascia 430 mm Royal Freestanding 1 Overall height 685 mm Overall width 860 mm Overall depth 450 mm...

Страница 31: ..._________________________________ ADDRESS____________________________________________________________ CITY STATE POSTCODE_______________________________________________ PURCHASED AT Dealer name addres...

Отзывы: