When the room temperature is approaching the set temperature, the flame will begin to diminish.
Once the room temperature reaches the set temperature the heater will go to minimum flame. If
the room temperature begins to fall the flame will then increase.
When the heater is turned off the room fan will continue to run for a further 2 minutes.
TURNING THE APPLIANCE OFF
Press power button on remote once. The room fan will continue to operate for a short period
while the heater cools down.
Please note:
1 This appliance cannot be operated without the fan running.
2 Due to the performance and efficiency of the heater, steam may be noticed coming from the
flue terminal on cool days.
3 As this appliance has a luminous effect some slight carbon deposition may occur
SAFETY FEATURES:
Automatic Pre-purge:
Before heater ignition this operation is done to evacuate any remains of
gas or flue products from inside the firebox that could be the cause of a mishap.
Automatic Shut-off:
Should the flame extinguish for any reason there is an
automatic shut off of the gas supply.
Over temperature protection:
In the event of the room fan failing, blockage of airways or
incorrect gas installation, the gas supply will automatically shut off after 5 minutes. This is due
to temperature increase and to prevent the appliance from over-heating.
Warning
:
This appliance must be installed to comply with AS/NZS 5601.1 codes
and regulations and only by a Coonara authorised technician who is responsible for its
correct operation at the time of installation and final commissioning
.
For your own convenience please record the following information in the space provided:
Purchased from:
Name…………………………………………………………………………
Address………………………………………………………………………
Phone No…………………………………..Date of purchase:…….………
Serial No of appliance:………………………………………………………
To be completed by the installer:
Name……………………………………………..Licence No……………….
Address………………………………………………………………………..
Phone No……………………………………. Installation Date…………….
Содержание Royal Classic
Страница 12: ...Revised 02 12 2015 2 12 2015 12...
Страница 13: ...Revised 02 12 2015 2 12 2015 13...
Страница 14: ...Revised 02 12 2015 2 12 2015 14 INBUILT INSTALLATION...
Страница 16: ...Revised 02 12 2015 2 12 2015 16...
Страница 17: ...Revised 02 12 2015 2 12 2015 17...
Страница 18: ...Revised 02 12 2015 2 12 2015 18...
Страница 19: ...Revised 02 12 2015 2 12 2015 19 SIDE VIEW REAR VIEW FRONT VIEW GRANGE ROYAL FREESTANDING 2 APPLIANCE DIMENSIONS...
Страница 21: ...Revised 02 12 2015 2 12 2015 21 WIRING DIAGRAM FOR THERMOSTAT Sit Gear Tray PRESSURE SWITCH...
Страница 24: ...Revised 02 12 2015 2 12 2015 24 STEP 2 STEP 3 STEP 4...
Страница 25: ...Revised 02 12 2015 2 12 2015 25 STEP 5 STEP 6 LOG SET FRONT VIEW...