INBUILT INSTALL INTO A STUD WALL CAVITY
1.
Mark the exact location of where the heater is to be located with an outline 720mm wide by
615mm high (minimum)
2.
Check that location for the flue terminal conforms to the requirements of AS/NZS5601.1
Location of a Flue Terminal.
3.
Cut out the plaster board and timber supports (re-position supports if necessary)
4.
Continue as described on previous page.
INBUILT INSTALLATION THROUGH A WALL
THAT REQUIRES A WEATHER COVER
1.
Mark the exact location of where the heater is to be located with an outline 720mm wide by
615mm high.
2.
Check that location for the flue terminal conforms to the requirements of AS5601.1 Location
of a Flue Terminal.
3.
Cut out the plasterboard and timber supports (re-position if necessary). Cut out the outer
brickwork.
4.
Fit the outer weather cover over the exposed heater body and screw to the outer wall. Also
use a silicon sealant.
5.
Feed the gas line through the hole located at the lower right hand side of the outer weather
cover (provided) and the flue pipes through the pre-punched hole for the flue pipes on the
upper left hand side.
6.
Locate the appliance. Connect gas.
7.
Fit the cowl back to the outer weather cover (Also use a silicon sealant). As page 13
instructions.
8.
Fit the cowl to the flue pipes and then to the weather cover.
9.
Install heater as per instructions on page 13.
INBUILT EXTERNAL WEATHER COVER
1. The weather cover has in the bottom RH corner a moveable plate for gas connections.
2. Pre punch holes to take cowl.
3. When the weather cover and cowl are attached it is necessary to seal the top and side edges
with silicone to prevent water entry.
IMPORTANT !
The Royal Classic, Slimline & Freestanding Gas Log Heaters must
be vented directly to the outside.
Содержание Royal Classic
Страница 12: ...Revised 02 12 2015 2 12 2015 12...
Страница 13: ...Revised 02 12 2015 2 12 2015 13...
Страница 14: ...Revised 02 12 2015 2 12 2015 14 INBUILT INSTALLATION...
Страница 16: ...Revised 02 12 2015 2 12 2015 16...
Страница 17: ...Revised 02 12 2015 2 12 2015 17...
Страница 18: ...Revised 02 12 2015 2 12 2015 18...
Страница 19: ...Revised 02 12 2015 2 12 2015 19 SIDE VIEW REAR VIEW FRONT VIEW GRANGE ROYAL FREESTANDING 2 APPLIANCE DIMENSIONS...
Страница 21: ...Revised 02 12 2015 2 12 2015 21 WIRING DIAGRAM FOR THERMOSTAT Sit Gear Tray PRESSURE SWITCH...
Страница 24: ...Revised 02 12 2015 2 12 2015 24 STEP 2 STEP 3 STEP 4...
Страница 25: ...Revised 02 12 2015 2 12 2015 25 STEP 5 STEP 6 LOG SET FRONT VIEW...