background image

Revised: 02/12/2015 

 

2/12/2015 

28

such  damage  is  caused  by  Coonara  negligence.    Normal  wear  and  tear  items  such  as 
routine surface maintenance, seals and door glass are also excluded from this warranty. 

6)

 

Shamic goods come with guarantees that cannot be excluded under Australian Consumer 
Law.  The  purchaser  is  entitled  to  a  replacement  or  a  refund  for  a  major  failure  and 
compensation  for  any  reasonably  foreseeable  loss  or  damage.  The  purchaser  is  also 
entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality 
and the failure does not amount to a major failure. 

7)

 

This warranty applies only to units purchased from an authorised dealer and the duration 
of this implied warranty, including merchantability, applicable to this Coonara heater is 
limited to the duration of the foregoing warranty. 

8)

 

Before  Shamic  Sheetmetal  (Aust.)  Pty.Ltd.  will  recognise  or  accept  a  claim  under  this 
warranty, you must provide proof of purchase.  On purchase of the heater, despatch your 
warranty card to Shamic Sheetmetal (Aust.) Pty.Ltd. 

9)

 

Your authorised dealer  must be notified of any  defect in the heater, for  investigation of 
the  claim.  Your  authorised  dealer  will  be  able  to  explain  the  process  of  making  a 
warranty  claim  and  any  costs  associated  with  returning  goods.  In  the  event  where  a 
remedy  is  necessary  and  the  claims  under  warranty  are  accepted,  the  purchaser  may  be 
required to return the goods to the authorised dealer for repair, replacement or refund. 

 

 

CARE OF YOUR ROYAL GAS HEATER 

 

This  appliance  requires  minimal  maintenance,  however,  it  is  recommended  that  a 
qualified person make a full service and check annually. 
The Bottom fascia air grill should be removed by unscrewing the two screws and 
the fan vacuumed annually.  
To clean the appliance, simply wipe over with a damp cloth.  Do not use solvents 
or abrasive cleaning agents.  
 
 
Before making a service call check that: 
 
 
1 - Electrical power is on  
 
2 - Gas is turned on 
 
3 - There are no obstruction /blockages of the flue terminal   

  
 
 
 
 
 
 

 

 

 

Содержание Royal Classic

Страница 1: ...r of Heater ____________ Model ___________________ Serial Number of Heater ____________ Model ________________ Royal Slimline Classic Freestanding Gas Heaters ARE AUSTRALIAN OWNED AND MANUFACTURED BY...

Страница 2: ...ilt models must be placed on 6mm AC sheeting to prevent unit from rattling Heater must be checked for scratches or dents prior to installation All glass must be fitted with a screw driver not a drill...

Страница 3: ...TY FEATURES 7 INSTALLATION INSTRUCTIONS 8 15 DIMENSIONS INBUILT MODELS 16 17 DIMENSIONS FREESTANDING MODEL 18 19 PRESSURE ADJUSTMENTS 20 WIRING DIAGRAM PRESSURE SWITCH 21 BURNER REMOVAL 22 LOG SET 23...

Страница 4: ...YTH VIC 3136 To be installed by a Coonara authorised technician in accordance with installation instructions provided with the appliance Electrical Conform to AS3100 240v 50Hz 120Watts Max Air Pressur...

Страница 5: ...aged it must be replaced with an original Coonara part obtainable from your authorized dealer THE SAFETY GUARD AROUND THE GLASS DOOR IS FITTED TO THIS APPLIANCE TO REDUCE THE RISK OF FIRE OR INJURY FR...

Страница 6: ...before automatically going to the higher flame setting 3 The fan will not start until the heater has reached the minimum operating temperature 4 During first time firing of this appliance an odour may...

Страница 7: ...Pre purge Before heater ignition this operation is done to evacuate any remains of gas or flue products from inside the firebox that could be the cause of a mishap Automatic Shut off Should the flame...

Страница 8: ...connection must be removed by using a Tin Snip or similar tool See page 12 SERVICE INSTRUCTIONS INBUILT To access flue fan the over temp switch and the thermistor the heater needs to be removed To ac...

Страница 9: ...ed both flexible pipes down the flue cavity 3 Fix flue terminal securely to top of the flue cavity and seal to prevent water entry Seal with Hi temperature waterproof silicon sealant prior to cementin...

Страница 10: ...r from the pallet 3 Position heater locate and connect flue pipes to unit Connect gas to the flexible connection line and check pressure coming in Minimum pressure required NAT GAS 1 1 High and low se...

Страница 11: ...ry Cut out the outer brickwork 4 Fit the outer weather cover over the exposed heater body and screw to the outer wall Also use a silicon sealant 5 Feed the gas line through the hole located at the low...

Страница 12: ...Revised 02 12 2015 2 12 2015 12...

Страница 13: ...Revised 02 12 2015 2 12 2015 13...

Страница 14: ...Revised 02 12 2015 2 12 2015 14 INBUILT INSTALLATION...

Страница 15: ...2 12 2015 2 12 2015 15 INBUILT REAR FLUE INSTALLATION WITH OPTIONAL OFFSET FLUE BOX INBUILT FREESTANDING The Offset Flue Box is used only when wall flue penetration has less than 300mm high from outsi...

Страница 16: ...Revised 02 12 2015 2 12 2015 16...

Страница 17: ...Revised 02 12 2015 2 12 2015 17...

Страница 18: ...Revised 02 12 2015 2 12 2015 18...

Страница 19: ...Revised 02 12 2015 2 12 2015 19 SIDE VIEW REAR VIEW FRONT VIEW GRANGE ROYAL FREESTANDING 2 APPLIANCE DIMENSIONS...

Страница 20: ...and adjusted and should not need to be re adjusted during installation Gas pressures still need to be checked to the pressures shown on Page 4 of this manual But there will be some situations where so...

Страница 21: ...Revised 02 12 2015 2 12 2015 21 WIRING DIAGRAM FOR THERMOSTAT Sit Gear Tray PRESSURE SWITCH...

Страница 22: ...rew in the lower centre of the heater that hold the Fascia in place Then lift and pull the fascia towards you This will unclip the two hanging hooks inbuilt only 2 Undo the two self taper screws below...

Страница 23: ...015 23 COONARA ROYAL SLIMLINE CLASSIC LOG SET LOCATION DETAILS All logs have self locating points moulded into them This allows for accurate positioning of logs DO NOT INSTALL LOG LIKE THIS STEP 1 Fix...

Страница 24: ...Revised 02 12 2015 2 12 2015 24 STEP 2 STEP 3 STEP 4...

Страница 25: ...Revised 02 12 2015 2 12 2015 25 STEP 5 STEP 6 LOG SET FRONT VIEW...

Страница 26: ...sold you the heater 5 Advise them of the specific problem 6 Provide the details that your retailer requests to complete a Warranty Claim Form This must include the heater model serial number and insta...

Страница 27: ...no responsibility for any damages that result due to installation or operation of the heater not in accordance with both the installation and operation instructions furnished with the unit c This war...

Страница 28: ...laim under this warranty you must provide proof of purchase On purchase of the heater despatch your warranty card to Shamic Sheetmetal Aust Pty Ltd 9 Your authorised dealer must be notified of any def...

Страница 29: ...rating Insufficient time allowed Loose wiring Fan not located correctly Fan blocked Fan has a delayed start and will not start until unit warms up Check wiring Install fan in correct location Remove a...

Страница 30: ...Overall depth 450 mm Packed Weight 90 kg Firebox Casing Height 600 mm Width 705 mm Depth from rear of fascia 430 mm Royal Freestanding 1 Overall height 685 mm Overall width 860 mm Overall depth 450 mm...

Страница 31: ..._________________________________ ADDRESS____________________________________________________________ CITY STATE POSTCODE_______________________________________________ PURCHASED AT Dealer name addres...

Отзывы: