C100E EtherCAT AC Servo Drive
www.coolmay.com
51
No.
Name
Function
Rang
Defa
ult
Value
is turned off.
55
Effective level
control word of
input terminals
1.To reverse the input terminals. For
unreversed terminals, it is valid when the
switch is closed, while it is invalid when the
switch is open. For reversed terminals, it is
invalid when the switch is closed, while it is
valid when the switch is open.
2.Represented by a binary digit of 4 bits. If
it is 0, it means the input terminal dose not
reverse. While it is 1, it means the terminal
reverses.
The binary digit represents the input
terminals as following:
3
2
1
0
DI4
DI3
DI2
DI1
0: high level is active.
1: low level is active.
0000-11
11
0000
57
Effective level
control word of
output terminals
1.To reverse the output terminals. For
reversed terminals,the definitions of
breaking over and cut-off is contrary to
standard definitions
2.Represented by a binary digit of 4 bits. If
it is 0, it means the input terminal dose not
reverse. While it is 1, it means the terminal
reverses.
The binary digit represents the input
0000-11
11
0000