C100E EtherCAT AC Servo Drive
www.coolmay.com
37
No.
Name
Function
Rang
Defa
ult
Value
great, reducing the setting value is
recommended. If the value is too small, it
would lead to low response, which would
result in shaking.
4.The value is bigger, the cut-off frequency
is higher and the response frequency is
quicker. If you need higher torque response
frequency, it is recommended to increase
the setting value.
8
Speed detection
filter
1. To set the characters of speed detection
filter.
2. The value is smaller, the cut-off
frequency is lower and noise from the
motor is smaller. If the load inertia is great,
reducing the setting value is recommended.
If the value is too small, it would lead to low
response, which would result in shaking.
3. The value is bigger, the cut-off frequency
is higher and the response frequency is
quicker. If you need higher torque response
frequency, it is recommended to increase
the setting value.
20-500
%
100
9
Proportional gain
of position loop
1.To set the proportional gain of position
loop .
2.The value is bigger, the gain is higher and
its rigidity is stronger. So the position lag is
1-1000
80