C100E EtherCAT AC Servo Drive
www.coolmay.com
55
No.
Name
Function
Rang
Defa
ult
Value
command pulse frequency: 500KHz(kpps). The value is
bigger, the max input frequency is slower.
3.To filter the noise from the signal line in
order
to
avoid
incorrect
counting
happening. If it goes wrong due to the
incorrect counting, you can increase the
value of this parameter properly.
4. After editing this parameter, please save
it and recharge. Then it is effective.
82
SIGN signal filter
of command
pulse
1.To filtering the input SIGN signal.
2.The default value is the max pulse input
frequency: 500KHz(kpps) The value is
bigger, the max input frequency is slower.
3.To filter the noise from the signal line in
order
to
avoid
incorrect
counting
happening. If it goes wrong due to the
incorrect counting, you can increase the
value of this parameter properly.
4. After edited this parameter, must save it
and recharge. Then it is effective.
0-15
1
83
CWL/CCWL
inhibit way
When the machine touches the mechanical
limit switch and strike CW/CCW limit , you
can choose the following methods to
prohibit with this parameters.
0: To limit the torque in this direction to be
0.
1: To prohibit the input pulse in this
0-1
0