![Coolmay C100E Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/coolmay/c100e/c100e_manual_2661264056.webp)
C100E EtherCAT AC Servo Drive
www.coolmay.com
50
No.
Name
Function
Rang
Defa
ult
Value
47
The setting of
mechanical brake
when the motor
stops
1.It defines the delay time from BRK=ON
and BRK=OFF to the motor current cutting
off when the motor stops rotating.
2.To avoid a small displacement or working
drop of the motor, the parameter should not
be less than the delay time of mechanical
braking.
0-200×1
0ms
0
48
The setting of
mechanical brake
when the motor
rotates
1. It defines the delay time from the motor
current cutting off to BRK=ON and
BRK=OFF when the motor rotates.
2.To avoid a damage to the brake, the
parameter makes the motor slow down and
then makes the mechanical brake work.
3. The actual action time is the time it takes
to drop from PA48 or current motor speed
to PA49, and taking the minimum value.
0-200×1
0ms
50
49
The working
speed of the
mechanical brake
when the motor
rotates
1. It defines the speed value from motor
current cut-off to mechanical brake action
(output terminal BRK from ON to OFF)
during motor working.
2.The actual action time is the time it takes
to drop from PA48 or current motor speed
to PA49, and taking the minimum value.
0-3000r/
min
100
50
Speed limit in
torque control
mode
1:In torque control mode, the motor running
speed is limited in the range of this
parameter.
2:It can prevent over speed in light load.
0-5000
r/min
3000
53
Servo force
enable
To set :
0: The enable signal is controlled by SON
of digital input(DI).
1:Software force to servo on.
0-1
0
54
The delay
closing time of
servo enable
It defines the time to delay cutting off the
motor current after the servo enable signal
0-30000
ms
0