SYMPTOM
PROBLEM
TEST SOLUTION
Main burner goes out; pilot
stays on.
Venting is spilling.
-
Test with spill switch bypassed.
-
Check for vent blockage.
CS280
SYMPTOM
PROBLEM
TEST SOLUTION
Main burner goes out; pilot
goes out.
Vent re-circulating.
-
Check joint seals and installation.
Main burner
fl
ame is a
blue, lazy, transparent
fl
ame.
Blockage in vent.
-
Remove blockage. In really cold conditions, ice buildup
may occur on the terminal and should be removed as
required.
Incorrect installation.
-
Ensure vent con
fi
guration is within prescribed venting
parameters
CDVS280
SYMPTOM
PROBLEM
TEST SOLUTION
SYMPTOM
PROBLEM
TEST SOLUTION
Pilot goes out
while standing:
Main burner is in
“OFF” position.
Gas piping is undersized.
-
Turn on all gas appliances and see if pilot
fl
ame
fl
utters, diminishes or extinguishes, especially
when main burner ignites. Monitor appliance supply
working pressure.
-
Check if supply piping size is to code. Correct all
undersized piping.
Remote wall
switch is in “OFF”
position; main
burner comes on
when gas knob
is turned to “ON”
position.
Wall switch is mounted
upside down.
-
Reverse.
Remote wall switch is
grounding.
-
Replace.
Remote wall switch wire
is grounding.
-
Check for ground (short); repair ground or replace
wire.
Faulty valve.
-
Replace.
Pilot is not
functioning
properly.
Pilot has been painted
-
Using a piece of sandpaper or emery cloth remove
the paint from the pilot hood, ignitor and
fl
ame sensor.
42 2 3A
42.3_3
SYMPTOM
PROBLEM
TEST SOLUTION
White / grey
fi
lm forms.
Sulphur from fuel is being
deposited on glass, logs or
combustion chamber surfaces.
-
Clean the glass with a recommended gas appliance
glass cleaner.
-
DO NOT CLEAN GLASS WHEN HOT.
-
If deposits are not cleaned off regularly, the glass may
become permanently marked.
Exhaust fumes smelled in
room, headaches.
Appliance is spilling.
-
Ensure exhaust bracket gasket seal.
-
Check door seal and relief
fl
ap seal.
-
Check for chimney blockage.
-
Check that chimney is installed to building code.
-
Room is in negative pressure; increase fresh air supply.
-
Check cap gasket on the
fl
ue pipe assembly.
Remote wall switch is in
’OFF’ position; main burner
comes on when gas knob
is turned to ‘ON’ position.
Wall switch is mounted upside down.
-
Reverse.
Remote wall switch is grounding.
-
Replace.
Remote wall switch wire is grounding.
-
Check for ground (short); repair ground or replace wire.
Faulty valve.
-
Replace.
Door Sticking
Dirt / dust adheres to the hinges;
is heated and burns causing
sticking.
-
Lift door from its hinges. Lubricate with high temp dry
graphite only. Replace.
-
NOTE: Due to the high temperatures that the hinges
experience, wet lubricants such as oil and WD40 will
cause the hinge to seize and are therefore not suitable.
Main burner goes out; pilot
goes out.
Thermocouple shorting or faulty.
-
Loosen and tighten thermocouple.
-
Clean thermocouple and valve connection.
-
Replace thermocouple.
Содержание CDVS280N
Страница 49: ...W415 1429 01 06 15 49 EN 16 0 SERVICE HISTORY 43 1...
Страница 50: ...W415 1429 01 06 15 50 EN 44 1 17 0 NOTES...
Страница 51: ...W415 1429 01 06 15 51 EN 44 1...
Страница 52: ...Scan this QR code for more information or visit our website at www napoleonfireplaces com support gs28...
Страница 102: ...FR 44 1 16 0 NOTES 102 W415 1429 01 06 15...
Страница 103: ...FR 44 1 103 W415 1429 01 06 15...
Страница 104: ...44 1...