4.7.2 INSTALLING NATURAL VENT
Follow the instructions of the natural vent manufacturer for chim-
ney installation.
A.
Remove and discard the two combustion air cover plates
and gaskets located on the rear panel of the appliance.
B.
Replace the four screws per side to secure the rear
panel to the appliance.
C.
Remove the spill switch bracket from the rear of the
adapter.
D.
Gently pull the two wire terminals (located inside the
7" (178mm)
fl
ue collar at the top of the appliance) out
approximately 8" (203mm).
E.
Bring the wires through the lower hole in the adapter and
out the spill switch opening. To pass the wires through the
hole more easily, temporarily tape the two terminals together.
F.
With the spill switch opening aligned to the back of the
appliance, push the crimped edge of the adapter in to the
appliance
fl
ue collar.
G.
Connect the wire terminals to the spill switch and re-secure
the bracket.
H.
Secure the terminal block into place as shown with the screw
supplied.
I.
Unscrew the wire access cover plate from the rear right hand
side below the
fi
rebox. Remove and discard the gasket.
Remove the knockout from the cover plate and insert the
protective bushing. Pull both spill switch wires through
the bushing taking up any slack. Replace the cover plate.
Connect one wire end to the terminal block and the other
end to terminal 1 of the gas valve. Connect the two wires
running down the left side of the
appliance from the on/off switch to
the remaining tab on the terminal
block and to terminal 3 on the gas
valve.
For aesthetics, the adapter
has been designed to accept a
standard matte black 7" (178mm) stove pipe and the decorative band (standard with the GS-150KT).
Both are available from your local authorized dealer / distributor.
4.7.3 NATURAL VENT
Attach the Natural Vent label, shown, in the control area of the appliance.
SWITCH
SPILL
ADAPTER
COMBUSTION AIR COVER
PLATES AND GASKET
TERMINAL BLOCK
WIRE ACCESS
COVER PLATE
NOTE: If not converting, the wires
are rated for high temperatures and
may remain as is in the unit collar.
ATTACH THIS LABEL IN THE CONTROL AREA OF THE APPLIANCE.
THIS APPLIANCE HAS BEEN CONVERTED TO A NATURAL VENT
MODEL.
ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DUE FOYER.
CET APPAREIL A ÉTÉ CONVERTI À UN MODÈLE À TIRAGE
NATUREL.
A / W385-0160
Содержание CDVS280N
Страница 49: ...W415 1429 01 06 15 49 EN 16 0 SERVICE HISTORY 43 1...
Страница 50: ...W415 1429 01 06 15 50 EN 44 1 17 0 NOTES...
Страница 51: ...W415 1429 01 06 15 51 EN 44 1...
Страница 52: ...Scan this QR code for more information or visit our website at www napoleonfireplaces com support gs28...
Страница 102: ...FR 44 1 16 0 NOTES 102 W415 1429 01 06 15...
Страница 103: ...FR 44 1 103 W415 1429 01 06 15...
Страница 104: ...44 1...