W415-1429 / 01.06.15
39
EN
8.3 BLOWER
REPLACEMENT
Blower replacement may be done through either the
fi
rebox or from the rear
of the appliance. Using the rear panel is recommended.
INSTALLATION THROUGH THE REAR PANEL :
FOR MODEL CDVS280
•
Turn off the electrical power and the gas supply to the
appliance.
•
Remove the two combustion air covers and gaskets held on with 4
screws each. Remove the rear panel held in place with 6 screws.
•
Remove the 2 screws holding the blower to its mounting plate. Disconnect
the two blower wires.
•
Replace the blower and reconnect the two wires.
When replacing the rear panel, ensure that the wires
are neither pinched nor interfere with the blower
operation. Ensure that the combustion air cover
plates and gaskets are properly installed and sealed.
FOR MODEL CS280
•
Turn off the electrical power and the gas supply to
the appliance.
•
Remove the 8 screws securing the air intake
manifolds to the rear panel. Remove the rear panel
held in place with 6 screws.
•
Remove the 2 screws holding the blower to its mounting plate. Disconnect the two blower wires.
•
Replace the blower and reconnect the two wires. When replacing the rear panel, ensure that the wires
are neither pinched nor interfere with the blower operation. Re-secure the air intake manifolds.
INSTALLATION THROUGH THE FIREBOX:
REPLACEMENT BLOWER ACCESS GASKET IS REQUIRED.
•
Turn off the electrical power and the gas supply to the appliance.
•
Open the lower control door, the two side doors, and the
fi
re viewing door. Remove the logs.
•
Remove the blower access plate held on with 8 screws.
•
Disconnect the two blower wires. Remove the blower
bracket held on with 2 screws.
•
Replace the blower using the existing bracket. Replace
the bracket/blower assembly on the appliance.
•
Reconnect the two wires. Hold the replacement gasket
in place and reattach the blower access plate. Replace
the logs. Close all doors.
Turn the gas supply and electricity back on.
Because the blower is thermally activated, when turned on, it will automatically start approximately 15-30
minutes after lighting the appliance and will run for approximately 30-45 minutes after the appliance has been
turned off. Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings causing irreparable damage and must be prevented from
coming into contact with the blower or its compartment.
Any damage resulting from this condition is not covered by the warranty policy.
black
white
red
BLOWER
THERMAL
SWITCH
VARIABLE
SPEED
SWITCH
BLOWER
SCREWS
AIR INTAKE MANIFOLDS
SCREWS
BLOWER ACCESS
PLATE
Содержание CDVS280N
Страница 49: ...W415 1429 01 06 15 49 EN 16 0 SERVICE HISTORY 43 1...
Страница 50: ...W415 1429 01 06 15 50 EN 44 1 17 0 NOTES...
Страница 51: ...W415 1429 01 06 15 51 EN 44 1...
Страница 52: ...Scan this QR code for more information or visit our website at www napoleonfireplaces com support gs28...
Страница 102: ...FR 44 1 16 0 NOTES 102 W415 1429 01 06 15...
Страница 103: ...FR 44 1 103 W415 1429 01 06 15...
Страница 104: ...44 1...