4. Functions
50
AD12-8(PM)
Stop Condition
The condition for controlling the stop of sampling can be selected from among the last sampling count,
input data comparison, and software abort.
The PC card stops sampling whenever an error occurs irrespective of the stop condition setting.
-
Last sampling count
The PC card stops sampling after storing input data to memory for the specified number of times of
sampling.
- Input
data
comparison
Once the PC card has started sampling, it compares the analog signal input through a specified
channel to the value of the preset comparison level. If the analog signal satisfies the condition, the
PC card stops sampling.
Level comparison conditions are set as two conditions: level and direction.
The above sketch shows that the level comparison condition is satisfied in the rising direction.
The stop condition is satisfied when the analog signal at the specified channel passes the
comparison level in the rising direction. Input data items are stored to memory, ending until those
at solid dots.
The above sketch shows that the level comparison condition is satisfied in the falling direction.
The stop condition is satisfied when the analog signal at the specified channel passes the
comparison level in the falling direction. Input data items are stored to memory, ending until
those at solid dots
If you set the level comparison directions to both directions, the start condition is satisfied when the
analog signal passes the level both in the rising and falling directions.
- Software
Sampling continues indefinitely in this mode. Sampling only stops in response to a software
command or an error.
Содержание AD12-8(PM)
Страница 1: ...PC HELPER Analog I O PC Card AD12 8 PM User s Guide CONTEC CO LTD ...
Страница 7: ...vi AD12 8 PM ...
Страница 15: ...1 Before Using the Product 8 AD12 8 PM ...
Страница 45: ...2 Setup 38 AD12 8 PM ...
Страница 67: ...4 Functions 60 AD12 8 PM ...
Страница 77: ...5 About Software 70 AD12 8 PM ...