3. External Connection
42
AD12-8(PM)
Analog Output Signal Connection
This section describes examples of connecting analog output signals using flat cable or shield cable.
The following is an example of how to connect using a cable such as a separately purchased flat cable
(PCA37P).
Connect the analog output and analog ground to the input and ground respectively on the external
device.
Digital Multi-Meter etc.
Analog Output
Analog Ground
CARD
Connector
Cable
Target
Figure 3.6. Analog Output Connection (Flat Cable)
The following figure shows an example of shielded cable connection. Use shielded cable if the
distance between the PC card and external device is long or if you want to provide better protection
from noise. For the CN1 analog output, connect the core wire to the signal line and connect the
shielding to ground.
Analog Ground
Shield cable
Analog Output
CARD
Connector
Target
Digital Multi-Meter etc.
Figure 3.7. Analog Output Connection (Shield Cable)
CAUTION
-
If the PC card or the connected wire receives noise, or the distance between the PC card and the
target is long, data may not be outputted properly.
-
For analog output signal, the current capacity is ±5mA (Max.). Check the specification of the
connected device before connecting the PC card.
-
Do not short the analog output signal to analog ground, digital ground, and/or power line. Doing
so may damage the PC card.
-
Do not connect an analog output signal to any other analog output, either on the PC card or on an
external device, as this may cause a fault on the PC card.
Содержание AD12-8(PM)
Страница 1: ...PC HELPER Analog I O PC Card AD12 8 PM User s Guide CONTEC CO LTD ...
Страница 7: ...vi AD12 8 PM ...
Страница 15: ...1 Before Using the Product 8 AD12 8 PM ...
Страница 45: ...2 Setup 38 AD12 8 PM ...
Страница 67: ...4 Functions 60 AD12 8 PM ...
Страница 77: ...5 About Software 70 AD12 8 PM ...