Safe-Lec 2 Conductor Bar Manual
SECTION 2 - OVERVIEW
246’ (75M) Max.
on all
bars unless otherwise
specified
8.0”
(203mm)
Anchor Point
59.0”
(1.5M) recommended
hanger spacing vertical entr
y. For
cur
ves and la
teral entr
y 44.3”
(1.125M)
End Cover
Hanger Clamp
Notes:
Maximum length without expansions; 492’
(150M),
use anchor clamp a
t center
Joint
Anchor Point
14’-9”
(4.5M)
Expansion Section
120’ (36.5M) Max.
Aluminum Bars
230’ (70M) Max.
Steel Bars
160’ (49M) Max.
Copper Bars
18”
(450mm) Recommended
6”
(150mm) Minimum
6”
(150mm) Minimum
Between components
Powerfeed
(Joint powerfeed) lands on
splice
Maximum
overhang
at end 12.0”
(305mm)
End Cover
Conductor Bar
Section 14’-9”
(4.5M)
Typical 3-Phase System Over
view
NO
TE
•
Dimensions are in Inches (mm).
•
Maximum Recommended Hanger Spacing:
»
1.5 Meters (59.0”) on straight runwa
ys
»
1.125 Meters (44.3”) on all La
teral Mount Systems and Cur
ved
Systems (cur
ved section onl
y)
ATTENTION
•
Cur
ved bar to be factor
y bent onl
y.
6” (
150mm
) Minimum