SECTION 9 - END CAP ONTO CONDUCTOR BAR ASSEMBLY
Galvanized Steel and Copper Conductor Bar Installation
Install end caps onto galvanized steel and copper conductor bars. See
Figure 20-1.
Tools Needed
• 10mm A/F open ended wrench
Installation
1. Fit bolt into joint plate (ensure tab captivates the head on the set screw).
2. Place bolt and joint plate assembly into conductor bar.
3. Place end cover clamp, washer, and nut over bolt and joint plate assemblies (ensure end cover clamp is flush with conductor bar
face).
4. Tighten nut to a recommended torque of 8 Nm (5-6 ft-lbs).
5. Push end cover over assembly (ensure bolt is located in point “A” on end cover).
NOTE:
Wings on Tab to
face upwards.
This face to be flush
with conductor face.
Figure 20-1
1. Nut
2. Washer
3. End Cover Clamp
4. Bolt
5. Joint Plate
6. End Cover
3
2
4
5
6
A
1