The Thomas and Betts (T&B) terminal part numbers are shown below for reference only. Dimensions shown are the maximum allowable
sizes. All powerfeeds must have expansion loops incorporated in their installation. Flexible cables are recommended for all powerfeed
and collector assemblies. The use of cables with solid (non-strained) conductor is NOT RECOMMENDED.
Powerfeed
p/n
Lug p/n
T&B p/n
Dim
“A”
Dim
“B”
Dim
“C”
Cable Size (AWG)
XA-310910B
XA-310101
E72
1.32
.60
5/16
6
XA-310201
F72
1.35
.60
5/16
4
XA-310301
G972
1.59
.69
5/16
1-2
XA-310601
J972
1.94
.84
5/16
1/0AN-2/0
XA-310401
L973
2.25
1.04
3/8
3/0AN-4/0
XA-310912B
XA-310701
M972
2.28
1.12
5/16
4/0AN - 250 kcmil
XA-310501
54178
2.33
1.25
5/16
300 kcmil
XA-310911
XA-310101
E71
1.13
.48
1/4
6
XA-310034B
XA-310101
D71
1.13
.48
1/4
8
SECTION 14 - TERMINAL GUIDELINES CHART