SECTION 1 - SAFETY

1.3. Personnel Requirements-Qualifications

 WARNING

Inadequately trained persons are at risk of injury!  
Improper use can result in serious personal injury or material damage. All activities must only be performed by qualified personnel.

1.3.1  Only persons who can be expected to perform their work reliably are acceptable personnel. People whose reactions are impaired by 

drugs, alcohol or medications, for example, are not authorized.

1.3.2 When selecting personnel, follow all age- and occupation-specific guidelines applicable at the location of use. 
1.3.3 The following qualifications are specified in the operating instructions for certain fields of activity.

1.3.4 Trained personnel and operators

•   Will have participated in a training session, given by the owner, on the tasks assigned to them and the potential hazards in case 

of improper conduct.

•  The owner of the machine or system must document that the appropriate training has taken place. 

1.3.5 Specialist personnel

•   Will consist of persons capable of performing assigned tasks and independently identifying and avoiding potential hazards based 

on their specialist training, knowledge and experience as well as their knowledge of the applicable regulations. Persons are 
deemed to be technically qualified if they have successfully completed training as a master electrician, apprentice electrician, 
electrical engineer or electrical technician. Persons are also considered technically qualified if they have been employed in an 
appropriate capacity for several years, receiving theoretical and practical training in that line, and their knowledge and skills have 
been tested by a specialist in the appropriate field of training. 

•   The machine or system owner must document that the appropriate certificates or other proofs of qualification have been or are 

being provided.

1.4 Personnel Requirements-Unauthorized Personnel

 WARNING

Danger due to unauthorized personnel!  
Unauthorized persons who do not meet the requirements described here are not acquainted with the dangers in the working area. Keep 
unauthorized personnel away from the working area. In case of doubt, address the person and direct them away from the working area. 
Stop working, as long as unauthorized persons are in the working area.

Содержание BridgeGuard Plus

Страница 1: ...BRIDGEGUARD PLUSTM MANUAL XA 579411 3 08 24 22 BridgeGuard PlusTM Installation Operation Maintenance Manual...

Страница 2: ...se once Buyer returns such goods FOB point of original shipment by Seller at the risk and cost of Buyer Goods replaced by Seller shall become the property of Seller There is no guarantee or warranty a...

Страница 3: ...pfler has the unique ability to offer a degree of service not found anywhere else Conductix Wamp er s team of highly quali ed service technicians and engineers have years of experience servicing our c...

Страница 4: ...Equipment 7 SECTION 2 PRODUCT DISPOSAL 8 2 0 Product Disposal Recycling 8 SECTION 3 OVERVIEW 9 11 3 0 General Product Overview 9 3 1 Specifications 9 3 2 Structure 10 3 3 Status Indicator Lights 10 3...

Страница 5: ...tial to cause severe injury death and or major equipment or property damage NOTE NOTE is used to alert you to installation operation programming or maintenance information that is important but not ha...

Страница 6: ...of performing assigned tasks and independently identifying and avoiding potential hazards based on their specialist training knowledge and experience as well as their knowledge of the applicable regul...

Страница 7: ...ork clothing Primarily for protection against entrapment by moving machine parts Work clothing must be close fitting with a low resistance to tearing it must have close fitting sleeves and no protrudi...

Страница 8: ...rn and disposal agreement disassembled components must be recycled as follows All metallic parts must be sorted and recycled by material type All plastic components must be sorted and recycled by mate...

Страница 9: ...inition Distance Measurement Technology Precise time of flight measurement Visible Laser Red Light IP 67 rated for indoor and outdoor use 100 240 V AC voltage supply Switching Output Relay Relay outpu...

Страница 10: ...tus Q1 Q2 3 Zero Level 7 LED Status Indicator 4 Mounting Hole M4 8 Control Elements 3 3 Status Indicator Lights 3 3 1 The sensor box for BridgeGuard Plus features status indicator LEDs that provide in...

Страница 11: ...2 Push and hold SELECT button for 3 4 seconds to enter TEACH MODE The top LED Q1 NEAR will light up 3 Push the SELECT button two more times so the Q1 NEAR and Q1 FAR LEDs are both lit 4 Push the SET...

Страница 12: ...r to I Beam web 4 0 1 Mount reflector to the I Beam using appropriate hardware See Figure 4 1 NOTE A spacer must be used between the I Beam s web and the reflector back plates A lock washer much be us...

Страница 13: ...Figure 7 2 WARNING Maximum sensor trigger distance should be no more than 115 feet NOTE The sensor can be mounted to the flange of the beam or other alternative surfaces Figure 4 2 4 5 6 3 1 2 Figure...

Страница 14: ...SECTION 4 INSTALLATION 4 2 Sensor Targeting 4 2 1 Included below is a general sensor target installation your specific installation may vary See Figure 4 4 Figure 4 4 End of Runway End of Runway Refl...

Страница 15: ...See Table 4 1 Terminal Wire Color Description 4 Brown 24VDC 5 7 Blue 24VDC 8 Black Q1 PNP Out 9 White Q2 PNP Out 10 Gray Teach Input Table 4 1 L 120V BLACK 18AWG 6 N 120V WHITE 18 AWG 6 PE GREEN 18AW...

Страница 16: ...4 5 3 Setting up SLOWDOWN distance detection 1 With the sensor mounted to the crane move crane to the SLOWDOWN distance point 2 Press and hold it will take approximately 5 seconds the SELECT pushbutt...

Страница 17: ...Electrical Maintenance WARNING Equipment damage due to improper cleaning Never use cleaning agents containing aggressive substance Never use pointed objects for cleaning Interval Maintenance Work To b...

Страница 18: ...sors and to the control box Unable to read output signals Electric Connection Inspect the connection to terminal blocks in control box and to the sensor Laser is not on reflector plate Realign sensor...

Страница 19: ...BRIDGEGUARD PLUSTM MANUAL 19 NOTES...

Страница 20: ...urlington ON L7L 0E6 Customer Support Phone 1 800 667 2487 Phone 1 450 565 9900 Fax 1 450 951 8591 info ca conductix com M XICO Calle Trevi o 983 C Zona Centro Apodaca NL M xico 66600 Customer Support...

Отзывы: