SECTION 4 - INSTALLATION
4.3 Controller
4.3.1 Below is the controller wiring diagram for reference if experiencing issues. See
Figure 4-5
NOTE:
• All dashed lines represent wiring that is field installed.
Figure 4-5
4.4 Electrical Installation
4.4.1 Sensor Cable Wiring
4.4.1.1 Use the Sensor Cable Wiring Table for sensor cable installation. See
Table 4-1.
Terminal
Wire Color
Description
4
Brown
+24VDC
5-7
Blue
-24VDC
8
Black
Q1 PNP Out
9
White
Q2 PNP Out
10
Gray
Teach Input
Table 4-1
L (120V) - BLACK, 18AWG, 6"
N (120V) - WHITE, 18 AWG, 6"
PE - GREEN, 18AWG, 6"
24V - BLACK, 18 AWG, 6",4",4"
24V + RED,
18AWG, 6"
Q2 SIGNAL (SLOW) BLUE, 18 AWG, 4"
Q1 SIGNAL (STOP) BLUE, 18 AWG, 4"
LINE (120)
NEUTRAL (120)
PE
24V + TO SENSOR
24V - TO SENSOR
Q1 SIGNAL FROM SENSOR
Q2 SIGNAL FROM SENSOR
ANALOG SIGNAL FROM SENSOR-PRO
NOT USED-PLUS
N.C. RELAY
RELAY COMMON
RELAY COMMON
N.C. RELAY
ANALOG SIGNAL TO
CONTROL DEVICE-PRO
NOT USED-PLUS
1 2 3
4 5 6 7
8 9 10
Q1 Q2