Error and Warning Codes
Warning and error messages triggered by the control software in the humidifier are shown below.
Error/Warning LED Interpretation
Description
Blinking
Security loop is open (W2).
Fading
(Red/Blue) Standby mode. Activate the humidifier through your
app and ensure the setpoint is between 40-60%.
Red
Unit is off (but still powered). Turn on the humidifier with the power
button.
Red
Yellow
No WiFi connection (W6).
Yellow
Cylinder end of life approaching expiry (W5).
Red
Red
Cylinder end of life reached (E5).
Red
Red
Invalid cylinder installed (E6).
Yellow
Control sensor broken (W3).
Yellow
Limiter sensor broken (W4).
Yellow
WiFi signal timeout reached (W6).
Red
Over current detected (E1).
Red
Inlet/Drain problem (E2).
Red
No current detected (E3).
Red
PCB error (E4).
Condair RH
2594949_B_EN_2005_Condair-RH_OM
Troubleshooting | 25