7.12.2 Manual cleaning:
Î
Turn the power off with the main dis-
connect switch on the power cabinet
Î
Disconnect compressed air
Î
Open front access door and remove
the weigh bin
Î
Position some type of deflector (card-
board tray) to divert material from col-
lecting in the mix chamber to an out-
side drum or bucket. Also available is
the Conair Drain Chute Accessory.
This allows the discharge valves to be
operated in the manual mode.
Î
Using a “dowel rod” approximately
12 inches long, press vertically into the
respective valve opening and raise the
plunger cone to allow material to flow
from the material compartments.
Î
Material will flow out of the hopper
compartment through the valve open-
ing onto the deflector and into the drum
or bucket.
Î
Discharge the material completely and
clean the material hopper from the top
down.
Î
You may also want to clean the mate-
rial receiver at this time while accessing
the gravity dump valve through the re-
spective blender clean out door.
Shown
with the
optional
drain
chute and
safety
interlock
The optional drain
chute is available
from Conair.
Contact Conair Parts
1 800 458 1960
From outside of the
United States, call:
814 437 6861
Содержание TrueBlend TB500-4
Страница 2: ......
Страница 138: ...Appendix TrueBlend 136 Edition February 2007 11 1 2 Menu overview dosing unit...
Страница 139: ...TrueBlend Appendix Edition February 2007 137 11 1 3 Menu overview conveying Optional...
Страница 140: ...Appendix TrueBlend 138 Edition February 2007 11 1 4 System settings menu...
Страница 141: ...TrueBlend Appendix Edition February 2007 139 11 1 5 Unit settings menu...
Страница 142: ...Appendix TrueBlend 140 Edition February 2007 11 1 6 Conveyor settings menu...