Maintenance and Repair
TrueBlend
™
118
Edition: February 2007
9.2 Before
starting
work
Before starting work, the following conditions must be met.
9.2.1 Switch off unit/disconnect from compressed air supply
WARNING!
D A N G E R O F I N J U R Y !
Rotating unit components can catch body parts and pull them in and cause
life-threatening crushing, shearing and bone fracture injuries.
Î
Set the unit main switch to "0" before starting maintenance and repair
work.
Î
Secure the unit to prevent unauthorized restart.
9.3 Inspections
9.3.1 Checking EMERGENCY STOP function
Procedure
Î
Actuate the EMERGENCY STOP switch (main switch to "0").
If the cone valve was open, it is closed. All other machine movement is stopped imme-
diately.
9.3.2 Testing safety interlock switch
Procedure
9.3.3 Test the safety interlock switch as described in 7.7.1
Checking functions in manual mode
.