UGH025-0504
Thermolator TW Series
T
ROUBLESHOOTING
6-27
R
EASSEMBLY
OF
M
OTORIZED
V
ALVES
Verify that the
valve is in the
closed position.
The position of
the ball opening
is indicated by
the index on top
of the shaft.
1
2 Slide the actuator
straight down
over the valve
shaft and onto the
mounting plate,
with the “R” side
facing up. On
MS40-703 mod-
els, the rotation
switch must be in
the “R” position.
Align the actuator
with the mount-
ing plate, then
slide the anti-
rotation clip half
way into the slot
on the bottom of
the actuator.
3
Tighten the wing
nut to secure the
anti-rotation clip
in place. Be care-
ful not to over-
tighten the wing
nut.
4
Clip with 2 Holes
(NYBA-200)
Using a 10 mm
wrench or socket,
evenly tighten the
two nuts on the
shaft clamp,
applying 8 to 10
lb-ft (11 to 14 N-
m) of torque.
5
Содержание Thermolator TW
Страница 68: ...Thermolator TW Series UGH025 0504 5 16 MAINTENANCE...
Страница 102: ...Thermolator TW Series UGH025 0504 6 34 TROUBLESHOOTING...
Страница 105: ...UGH025 0504 Thermolator TW Series APPENDIX B 1 PUMP CURVES...
Страница 106: ......
Страница 108: ......
Страница 113: ...PD 1 UGH025 0504 Thermolator TW Series l TW 1 Circuit Board PD 2 l TW 2 Circuit Board PD 3 PARTS DIAGRAMS...
Страница 114: ...TW 1 CIRCUIT BOARD UGH025 0504 PD 2...
Страница 115: ...UGH025 0504 TW 2 CIRCUIT BOARD PD 3...
Страница 116: ......