UGH025-0504
Thermolator TW Series
I
NSTALLATION
3-3
The Thermolator is easy to install, if you plan the location and
prepare the area properly.
Position the Thermolator as close to the
process machine as possible.
Make sure the installation area provides:
r
A three-phase power source supplying the correct
current for your Thermolator model. Check the serial tag
on the side of the electrical enclosure for the required
voltage, phase, frequency, full load amps, disconnect fuse
size and minimum wire connection size. Field wiring
should be completed by qualified personnel to the planned
location for the Thermolator. All electrical wiring should
comply with your region’s electrical codes.
r
A clean, well-ventilated environment.
The room temperature should not exceed 120°F (48°C)
with 95% non-condensing humidity and should not fall
below 32°F (0°C).
r
Minimum clearance for safe operation and
main-
tenance. The diagram at right shows minimum clear-
ance for operation. You also need enough clearance in
the rear for water hookups. For maintenance, you
should move the Thermolator to provide at least 36 inches
on any side of the Thermolator.
r
A source of water for cooling.
City, tower or chiller water may be used. The minimum
supply pressure is 25 psi and the maximum pressure is
shown in the following chart.
Install plumbing for process and cooling lines.
You will need two 1
1
/
4
-inch NPT male fittings for the
process inlet and outlet and two 3/4-inch NPT male fit-
tings for the cooling inlet and outlet. Larger line sizes are
acceptable as long as they are reduced at the Thermolator
connections. Smaller line sizes are not recommended.
P
REPARING FOR
I
NSTALLATION
1
TW Microproces
sor Control
Heat On
Cool On
High Temp A
larm
Setpoint Dev
iation Alarm
Communication
s Active
Process
Value
Set
Value
Err.H = Open
Thermocoup
le
Err.L = Reve
rsed Thermo
couple
Parameter
Access
Increase
Decrease
Mode
Stop Pump
Start
Depress until
vent cycle
ends and pum
p starts
Alarm
Purge
Push On/ Off
Control Pow
er
Push On/ Of
f
Fault
Push To Silen
ce
2
Process machine
Thermolator
Alternate
locations
3
12 inches
(305 mm)
12 inches
(305 mm)
20 inches
(508 mm)
Pump HP Max Cooling
3/4 HP 95 PSI
1 85
2 70
3 70
5 60
7
1
/
2
50
Содержание Thermolator TW
Страница 68: ...Thermolator TW Series UGH025 0504 5 16 MAINTENANCE...
Страница 102: ...Thermolator TW Series UGH025 0504 6 34 TROUBLESHOOTING...
Страница 105: ...UGH025 0504 Thermolator TW Series APPENDIX B 1 PUMP CURVES...
Страница 106: ......
Страница 108: ......
Страница 113: ...PD 1 UGH025 0504 Thermolator TW Series l TW 1 Circuit Board PD 2 l TW 2 Circuit Board PD 3 PARTS DIAGRAMS...
Страница 114: ...TW 1 CIRCUIT BOARD UGH025 0504 PD 2...
Страница 115: ...UGH025 0504 TW 2 CIRCUIT BOARD PD 3...
Страница 116: ......