UGH025-0504
Thermolator TW Series
A
PPENDIX
D-1
The SPI commands supported by Conair Thermolator
®
mold
temperature controllers are listed in the following tables.
The standard required commands and three optional com-
mands are listed in the SPI Command Pairs table, along with
the Select and Poll command pairs in hexadecimal format.
Select commands set or change Thermolator functions. Poll
commands retrieve information from the Thermolator.
See
SPI S
TATUS
W
ORDS
for status words and BIT positions for
Process Status, Machine 1 Status and Machine 2 status.
For more information on the SPI protocol, you can obtain the
SPI Communication Protocol Manual by contacting:
The Society of the Plastics Industry, Inc.
1801 K Street, NW
Suite 600K
Washington DC 20006
(202) 974-5200
Fax: (202) 296-7005
www.plasticsindustry.org
SPI Command Pairs
Mold temperature controllers Device ID: hex 20
Commands Select Poll
Echo
0x20 0x20
- Select stores 4 bytes of information at the Thermolator; Poll retrieves it.
0x21 0x20
Version
0x20
- Retrieves 4 bytes of SPI version information.
0x22
Setpoint Process Temperature
0x20 0x20
- Sets and retrieves the process temperature setpoint.
0x31 0x30
Alarm, High Temperature Deviation*
0x20 0x20
- Sets the alarm band temperature; retrieves se alarm band value.
0x33 0x32
Alarm, Low Temperature Deviation*
0x20 0x20
- Sets the alarm band temperature; retrieves se alarm band value.
0x35 0x34
Process Status
0x20
- Retrieves run status and alarm conditions.
0x40
Status, Machine 1
0x20
- Retrieves run status and alarm conditions.
0x42
Status, Machine 2
0x20
- Retrieves run status and alarm conditions.
0x44
Mode, Machine
0x20 0x20
- Start/stops the Thermolator; acknowledges alarms; retrieves run status
0x49 0x48
Temperature, to Process
0x20
- Retrieves the actual temperature of fluid leaving to the Thermolator.
0x70
Temperature, from Process
0x20
- Retrieves the actual temperature of fluid returning to the Thermolator.
0x72
* NOTE: Both High and Low Temperature Deviation commands set the
same variable. Use only one of these commands to avoid problems.
TW-1, TW-2
C
ONTROLS
SPI
C
OMMANDS
S
UPPORTED BY
THE
C
ONAIR
T
HERMOLATOR
®
Содержание Thermolator TW
Страница 68: ...Thermolator TW Series UGH025 0504 5 16 MAINTENANCE...
Страница 102: ...Thermolator TW Series UGH025 0504 6 34 TROUBLESHOOTING...
Страница 105: ...UGH025 0504 Thermolator TW Series APPENDIX B 1 PUMP CURVES...
Страница 106: ......
Страница 108: ......
Страница 113: ...PD 1 UGH025 0504 Thermolator TW Series l TW 1 Circuit Board PD 2 l TW 2 Circuit Board PD 3 PARTS DIAGRAMS...
Страница 114: ...TW 1 CIRCUIT BOARD UGH025 0504 PD 2...
Страница 115: ...UGH025 0504 TW 2 CIRCUIT BOARD PD 3...
Страница 116: ......