114 - Managing the DeviceMaster
DeviceMaster Installation and Configuration Guide
: 2000594 Rev. F
Managing the DeviceMaster
Changing the Bootloader Timeout
If SocketServer fails during the upload process, you should change the
Bootloader
timeout
value to 45 seconds.
Note:
The DeviceMaster must be able to communicate using an IP address, which is compatible with this local
network. If necessary, refer to
Configuring the Network Settings
You must meet these requirement to use this procedure.
•
NS-Link device driver assembly v10.xx or higher installed
•
SocketServer v11.xx or higher loaded on the DeviceMaster
•
PortVision DX installed
Note:
If you cannot meet these requirements, you can use RedBoot to change the timeout value. See
PortVision DX - Changing Bootloader Timeout
Use the following procedure to change the Bootloader timeout to 45 seconds. You can use this procedure to
return the Bootloader timeout to 15 seconds after you have successfully uploaded SocketServer.
1.
If necessary, start PortVision DX, from
Comtrol > PortVision DX > PortVision DX
.
2.
Right-click the DeviceMaster in the
Device Tree
or
Device List
pane and click
Properties
.
3.
Type 45 in the
Bootloader Timeout
text box and click
Apply
.
Note:
You should return the Bootloader Timeout value back to 15 seconds after you upload SocketServer.