MNC-0400-048
14 of 14
Revision B
Operation, TWTA ODU Amplifier
WG Arc 2
Waveguide Arc Fault 2 on a
multi-waeguide arc
configuration.
A waveguide arc
was detected after
the isolator.
Check for properly
connected
waveguide, and a
properly terminated
load.
Wvgd Arc
Waveguide Arc Fault
A waveguide arc
was detected.
Check for properly
connected
waveguide, and a
properly terminated
load.
Table 1 TWT Fault Log Troubleshooting
Fault Log
Engry
Description
Possible Cause of
Fault
Action Needed to
Clear Fault