Remote Control Operation
SMS-7000 Modem Protection Switch
A–6
Rev. 3 Draft
A.3 Configuration
Commands/Responses
A.3.1 Backup
Modem
Backup
Modem
Address
Command:
Response:
Status:
Response:
<add/ADD_Bx_yyy'cr'
>add/ADD_Bx_yyy'cr''lf']
<add/ADD_Bx_'cr'
>add/ADD_Bx_yyy'cr''lf']
Where:
x = 1 or 2 (backup modem number).
yyy = 0 to 255 (backup modem address; 0 places backup
modem out of service).
Backup
Modulator
Active
(Enable)
Command:
Response:
Status:
Response:
<add/MA_Bx_yyy'cr'
>add/MA_Bx_yyy'cr''lf']
<add/MA_Bx'cr'
>add/MA_Bx_yyy'cr''lf']
Where:
x = 1 or 2 (backup modem modulator number).
yyy = YES or NO.
Note: Enter command in Manual mode only.
Backup
Demodulator
Active
(Enable)
Command:
Response:
Status:
Response:
<add/DA_Bx_yyy'cr'
>add/DA_Bx_yyy'cr''lf']
<add/DA_Bx'cr'
>add/DA_Bx_yyy'cr''lf']
Where:
x = 1 or 2 (backup modem demodulator number).
yyy = YES or NO.
Note: Enter command in Manual mode only.
Switching
Mode
Selection
Command:
Response:
Status:
Response:
<add/SM_Bx_yyy'cr'
>add/SM_Bx_yyy'cr''lf']
<add/SM_Bx'cr'
>add/SM_Bx_yyy'cr''lf']
Where:
x = 1 or 2 (backup modem number).
yyy = IND (Independent) or DEP (Dependent).
Note: Enter command in Manual mode only.
Prime
Modem
Assign.
Command:
Response:
Command:
Response:
Status:
Response:
<add/PMA_Bx_yyyyyyyy'cr'
>add/PMA_Bx_yyyyyyyy'cr''lf']
or
<add/PMA_Bx_'cr'
>add/PMA_Bx_'cr''lf']
<add/PMA_Bx'cr'
>add/PMA_Bx_yyyyyyyy'cr''lf']
Where:
x = 1 or 2 (backup modem number).
y = prime modems 1 through 8. (Each 'm' digit represents
a prime modem assigned to a backup modem, i.e.,
<add/PMA_B1_1234 would assign prime modems 1
through 4 to backup #1. If the 'm' digit is omitted following
the '_', then all prime modems will be removed from the
backup modem.)
Notes:
1. In a 1:4 configuration, in which one backup modem is
assigned to 4 prime modems, and the other backup
modem is assigned to the other 4 prime modems,
one backup modem switching mode can be
independent and the other dependent.
2. In a 2:8 configuration in which both backup modems
are assigned to the same prime modem, the backup
modem switching modes must both be the same.
3. Enter command in Manual mode only.
Backup
Multiplexer
Unit
Attached
Command:
Response:
Status:
Response:
<add/MU_Bx_yyy'cr'
>add/MU_Bx_yyy'cr''lf']
<add/MU_Bx'cr'
>add/MU_Bx_yyy'cr''lf']
Where:
x = 1 or 2 (backup multiplexer number).
yyy = YES or NO.
Содержание SMS-7000
Страница 2: ......
Страница 6: ......
Страница 8: ......
Страница 34: ...Introduction SMS 7000 Modem Protection Switch 1 14 Rev 3 This page is intentionally left blank...
Страница 43: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 9 Figure 2 1 Top Mount Installation...
Страница 45: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 11 Figure 2 2 Back Mount Hinge Installation...
Страница 70: ...Installation SMS 7000 Modem Protection Switch 2 36 Rev 3 This page is intentionally left blank...
Страница 76: ...Operation SMS 7000 Modem Protection Switch 3 6 Rev 3 This page is intentionally left blank...
Страница 83: ...SMS 7000 Modem Protection Switch Operation Rev 3 3 13 This page is intentionally left blank...
Страница 104: ...Operation SMS 7000 Modem Protection Switch 3 34 Rev 3 This page is intentionally left blank...
Страница 106: ...Theory of Operation SMS 7000 Modem Protection Switch 4 2 Rev 3 Figure 4 1 IF Switch Block Diagram...
Страница 112: ...Theory of Operation SMS 7000 Modem Protection Switch 4 8 Rev 3 This page is intentionally left blank...
Страница 142: ...M 2000 Multiplexer Utilization SMS 7000 Modem Protection Switch B 4 Rev 3 This page is intentionally left blank...
Страница 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...