SMS-7000 Modem Protection Switch
Operation
Rev. 3
3–15
3.4.3
Configuration Dependent Prime 1 through 8 Menu
Refer to Figure 3-5.
PRIME MODEM #n
ADDRESS
Set # other than 0. Address 0 is a global address.
Upon entry, the current status is displayed. Press [
↑
] or [
↓
] to make
the selection. Press [ENTER] to execute the change.
PRIME MOD #n
Must be On for the switch to recognize as active.
Upon entry, the current status is displayed. Press [
↑
] or [
↓
] to make
the selection. Press [ENTER] to execute the change.
PRIME DEMOD #n
Must be On for the switch to recognize as active.
Upon entry, the current status is displayed. Press [
↑
] or [
↓
] to make
the selection. Press [ENTER] to execute the change.
PRIME MODEM #n
PRIORITY
Options: LOW, MEDIUM, and HIGH.
Upon entry, the current status is displayed. Press [
↑
] or [
↓
] to make
the selection. Press [ENTER] to execute the change.
PRIME MODEM #n
DELAY
AUTO = 2 times sweep period
MANUAL = 0.5 to 127.0 SEC.
To switch properly in DEPENDENT mode, the Prime modem demods
must have input from a source modem other than their own. Otherwise,
when the delay is set to NONE, the switch will oscillate between prime
and backup modems. This occurs because the output of the modulator
has been interrupted while the whole modem attempts to switch.
Upon entry, the current status is displayed. Press [
↑
] or [
↓
] to make
the selection. Press [ENTER] to execute the change.
PRIME #n MULTIPLEXER
Displayed if multiplexer is; ‘YES or NO.’
Upon entry, the current status is displayed. Press [
↑
] or [
↓
] to make
the selection. Press [ENTER] to execute the change.
PRIME DEMOD #n
MULTIPLEXER
ADDRESS
(Menu applies, only if
multiplexer is attached.)
Set # other than 0. Address 0 removes the multiplexer from the system.
Address: 0 to 255
Upon entry, the current status is displayed. Press [
↑
] or [
↓
] to make
the selection. Press [ENTER] to execute the change.
BREAKOUT #n
CONFIGURATION
Press [ENTER] to access submenus.
D & I
Use the BNC connectors for Unbalanced.
Use the DB15 connector for Balanced.
EXTERNAL CLOCK
Use the BNC connectors for Unbalanced.
Use the DB15 connector for Balanced.
INSERT DATA INPUT
Options: NORMAL/LOOP
Select LOOP if insert clock is selected as receive buffer clock source at
the modem. This connects DDO to IDI. (Drop Data Out to Insert Data
In).
Содержание SMS-7000
Страница 2: ......
Страница 6: ......
Страница 8: ......
Страница 34: ...Introduction SMS 7000 Modem Protection Switch 1 14 Rev 3 This page is intentionally left blank...
Страница 43: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 9 Figure 2 1 Top Mount Installation...
Страница 45: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 11 Figure 2 2 Back Mount Hinge Installation...
Страница 70: ...Installation SMS 7000 Modem Protection Switch 2 36 Rev 3 This page is intentionally left blank...
Страница 76: ...Operation SMS 7000 Modem Protection Switch 3 6 Rev 3 This page is intentionally left blank...
Страница 83: ...SMS 7000 Modem Protection Switch Operation Rev 3 3 13 This page is intentionally left blank...
Страница 104: ...Operation SMS 7000 Modem Protection Switch 3 34 Rev 3 This page is intentionally left blank...
Страница 106: ...Theory of Operation SMS 7000 Modem Protection Switch 4 2 Rev 3 Figure 4 1 IF Switch Block Diagram...
Страница 112: ...Theory of Operation SMS 7000 Modem Protection Switch 4 8 Rev 3 This page is intentionally left blank...
Страница 142: ...M 2000 Multiplexer Utilization SMS 7000 Modem Protection Switch B 4 Rev 3 This page is intentionally left blank...
Страница 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...