Ku-Band Solid-State Power Amplifier
Revision 0
Remote Control
MN/KPA.IOM
6-11
Auto Fault
Recovery
Set Fault Recovery:
Confirmation:
Retrieve Status:
Confirmation:
<DEV/AFR_xxx'cr'
>DEV/AFR_xxx'cr'' lf']
<DEV/AFR_xxx'cr'
>DEV/AFR_xxx'cr'' lf']
Where xxx = On or Off
The default is Off.
The KPA output automatically muted in the
event of a detected fault. Auto Fault Recovery,
if enabled, will cause the output signal to go
active (unmuted) if all faults clear. If disabled,
the output will remain muted even after all
faults clear until a MUT_OFF command is
received.
6.9.3 Mode
Commands
Note :
There are two modes of operation that may intersect: Redundancy Mode and
Automatic Mode.
Redundancy Mode
Comtech EF Data’s KPA family is designed to automatically sense and configure into redundancy mode when the
redundant loop cable is connected. Polling on the dedicated redundancy buss will not begin until the redundancy loop
cable is connected. Each KPA’s designation in a redundant subsystem is determined automatically via the
redundancy interface cable connected between the two (1:1 subsystem) or three (1:2 subsystem) KPAs in the
redundant subsystem.
Automatic/Manual
Mode
Select Automatic Mode:
Confirmation:
Automatic Status:
Confirmation:
<DEV/SAM_y'cr' xxx
>DEV/SAM_y'cr'' lf']
<DEV/SAM_'cr'
>DEV/SAM_y'cr'' lf']
Where: y = A for Auto
M for Manual
The default is Off.
This command provides for automatic
switching by the backup KPA if both units are
in the Redundancy Mode. This command is
only accepted by the backup KPA. If a primary
KPA is set in Manual Mode and a fault occurs,
the backup KPA will log the occurrence and
not act upon further information from the KPA
until put into Automatic Mode.
Backup Mode
Initiate a Backup:
Confirmation:
Retrieve Backup Status:
Confirmation:
<DEV/FBU_x_y'cr'
>DEV/FBU_x_y'cr'' lf']
<DEV/FBU_'cr'
>DEV/FBU_zzzzz'cr'' lf']
Where: x = 1 or 2 KPA number.
Y = F to force a backup
N = to remove a backup
zzzzz = NONE, if no backup active.
ACTIVE, if an automatic backup
has occurred.
FORCED, if a forced backup is
active.
This command allows the user to force a
backup condition for mainternace and test
purposes. This command must be sent to the
KPA designated as the backup KPA to
configure the Waveguide switch to a position
such that the backup KPA is Online and the
primary KPA is Offline.
Priority Select
Set Prority:
Confirmation:
Retrieve Prority Status:
Confirmation:
<DEV/PRI_x'cr'
>DEV/PRI_x'cr'' lf']
<DEV/PRI_'cr'
>DEV/PRI_x'cr'' lf']
Where x = 1 or 2
This command allows the user to assign
prority when operating in a 1:2 redundant
subsystem. This command provides
arbitration in the event that both primary KPAs
are faulted simulataneously.
Содержание KPA-020IN
Страница 2: ......
Страница 13: ...Ku Band Solid State Power Amplifier Revision 0 Preface MN KPA IOM xi NOTES...
Страница 17: ...Ku Band Solid State Power Amplifier Revision 0 Introduction MN KPA IOM 1 4 Figure 1 3 Block Diagram of KPA 040...
Страница 23: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 2 4 Figure 2 1 Redundancy Installation 1...
Страница 31: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 6 NOTES...
Страница 33: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 8 NOTES...
Страница 59: ...Ku Band Solid State Power Amplifier Revision 0 Redundant Configuration MN KPA IOM 5 6 NOTES...
Страница 87: ...Ku Band Solid State Power Amplifier Revision 0 Maintenance and Troubleshooting MN KPA IOM 7 6 NOTES...
Страница 99: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...