![Comtech EF Data KPA-020IN Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/comtech-ef-data/kpa-020in/kpa-020in_installation-and-operation-manual_2648387066.webp)
Ku-Band Solid-State Power Amplifier
Revision 0
Remote Control
MN/KPA.IOM
6-7
6.7.5 Device
Address
The Device Address consists of a Physical Address. For this document DEV is used for
the generic case examples.
For Example;
<10
direct addressing
<10V2 indirect addressing
6.7.6 Command
A Command is a variable length character string beginning with a / and containing either
an instruction or an instruction and data for an KPA to act upon.
•
If data is passed by command, it is appended to the instruction by an
underscore( _ ).
•
If data is retrieved by command, underscore follows the instruction flagging
the KPA to supply data in a response.
•
In this document /COM is used for the generic case examples.
For Example:
<DEV/COM_xxx'cr'
Sends data to an KPA.
For Example:
<DEV/COM_'cr'
Requests information from an
KPA.
6.8 Confirmation
Response
A confirmation will change the start character, and echo the Device Address and
Command. Any requested data will be appended to the Command.
For Example:
>DEV/COM_xxx'cr''lf']
6.8.1 Error
Response
If an KPA cannot execute a Command or detects a protocol violation, an error response is
generated. An error is flagged by changing the "/" command designator in the response to
a "?". Following the "?" error symbol are two characters which are unique error symbols
useful for computer analysis. The two error symbols are followed by a text string
explaining the error for the convenience of a human operator. For this document ER is
used for the generic case examples response.
For Example:
>DEV?COM ER Error Message 'cr''lf']
Содержание KPA-020IN
Страница 2: ......
Страница 13: ...Ku Band Solid State Power Amplifier Revision 0 Preface MN KPA IOM xi NOTES...
Страница 17: ...Ku Band Solid State Power Amplifier Revision 0 Introduction MN KPA IOM 1 4 Figure 1 3 Block Diagram of KPA 040...
Страница 23: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 2 4 Figure 2 1 Redundancy Installation 1...
Страница 31: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 6 NOTES...
Страница 33: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 8 NOTES...
Страница 59: ...Ku Band Solid State Power Amplifier Revision 0 Redundant Configuration MN KPA IOM 5 6 NOTES...
Страница 87: ...Ku Band Solid State Power Amplifier Revision 0 Maintenance and Troubleshooting MN KPA IOM 7 6 NOTES...
Страница 99: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...