6-6
6.7 Addressess
All KPAs are addressed in a command by the Device Address. The Device Address
consists of a physical address or a physical address plus a virtual address.
6.7.1 Physical
Address
Each KPA in the system must have a unique physical address regardless of the access
method used. The physical address consists of a string of 1, 2 or 3 numbers from 1 to
256. The physical address is entered into a KPA via the front panel. For Direct Access,
the physical address is the only address required to command a KPA. A backup KPA or a
stand-alone KPA can only be accessed with a physical address.
For Example:
10
Addresses KPA whose physical address is 10.
6.7.2 Virtual
Address
In order to access an KPA controlled by a backup KPA indirectly, a virtual address is
required. A virtual address is appended to the physical address of the backup KPA with a
“V”. The virtual address is either the number “1" or “2" corresponding to the KPA’s
designation in a redundant subsystem.
For Example:
10V2
Addresses second KPA in a 1:2
redundant subsystem controlled by
the backup KPA whose physical address is 10.
6.7.3 Message
Structure
The structure of either a Command, Response, or Error Message is as follows:
•
Start Character
•
Device Address
•
Command or Response
•
End of Message String
6.7.4 Start
Character
The Start Character begins each message:
For Example:
<
Start of a user Command.
>
Start of a KPA response.
Содержание KPA-020IN
Страница 2: ......
Страница 13: ...Ku Band Solid State Power Amplifier Revision 0 Preface MN KPA IOM xi NOTES...
Страница 17: ...Ku Band Solid State Power Amplifier Revision 0 Introduction MN KPA IOM 1 4 Figure 1 3 Block Diagram of KPA 040...
Страница 23: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 2 4 Figure 2 1 Redundancy Installation 1...
Страница 31: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 6 NOTES...
Страница 33: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 8 NOTES...
Страница 59: ...Ku Band Solid State Power Amplifier Revision 0 Redundant Configuration MN KPA IOM 5 6 NOTES...
Страница 87: ...Ku Band Solid State Power Amplifier Revision 0 Maintenance and Troubleshooting MN KPA IOM 7 6 NOTES...
Страница 99: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...