Ku-Band Solid-State Power Amplifier
Revision 0
Remote Control
MN/KPA.IOM
6-9
6.9 Command/Response
Pairs
6.9.1 Utility
Commands
Time Set
Time:
Confirmation:
Retrieve Time:
Confirmation:
<DEV/TIM_hh:mm:ss'cr'
>DEV/TIM_hh:mm:ss 'cr'' lf']
<DEV/TIM_'cr'
>DEV/TIM_hh:mm:ss 'cr'' lf']
Where: hh = Hour
mm = Minutes
ss = Seconds
Note: 24-hour military is used.
Date Set
Date:
Confirmation:
<DEV/DAT_mm/dd/yy'cr'
>DEV/DAT_mm/dd/yy/'cr'' lf']
Where: mm = Month
dd = Day
yy = Year
Physical Address
Set Physical Address :
Confirmation:
Retrieve Physican
Address:
Confirmation:
<DEV/SPA_xxx'cr'
>DEV/SPA_xxx'cr'' lf']
<DEV/SPA_'cr'
>DEV/SPA_xxx'cr'' lf']
Where: xxx = 1 to 255
The default physical address is 1.
Baud Rate
Set Baud Rate:
Confirmation:
Retrieve Baud Rate:
Confirmation:
<DEV/SBR_xxxx'cr'
>DEV/SBR_xxxx'cr'' lf']
<DEV/SBR_xxxx'cr'
>DEV/SBR_xxxx'cr'' lf']
Where: xxxx = 300, 1200, 2400,
4800, or 9600
The default baud rate is 9600.
Parity Bit
Set Parity Bit:
Confirmation:
Retrieve Parity Bit:
Confirmation:
<DEV/SPB_xxxx'cr'
>DEV/SPB_xxxx'cr'' lf']
DEV/SPB_'cr'
DEV/SPB_xxxx'cr'' lf']
Where: xxxx = Odd or Even
The default parity is Even.
LCD Contrast
Set Contrast:
Confirmation:
Retrieve Contrast:
Confirmation:
<DEV/CON_xx'cr'
>DEV/CON_xx'cr'' lf']
<DEV/CON_'cr'
>DEV/CON_xx'cr'' lf']
Where: xx = 0 to 30
The default is contrast 15.
LCD Brightness
Set Brightness:
Confirmation:
Retrieve Brightness:
Confirmation:
<DEV/LCD_xx'cr'
>DEV/LCD_xx'cr'' lf']
<DEV/LCD_'cr'
>DEV/LCD_xx'cr'' lf']
Where xx = 0 to 30
The default is contrast 15.
Lamp Test
KPA-020IN
Test Lamps:
Confirmation:
Lamp Test Status:
Confirmation:
<DEV/LAM_xxx'cr'
>DEV/LAM_xxx'cr'' lf']
<DEV/LAM_'cr'
>DEV/LAM_xxx'cr'' lf']
Where: xxx = On or Off
Equipment Type
Retrieve Equipment Type:
Confirmation:
<DEV/RET_'cr'
>DEV/RET_xxxxxxx yyyyy'cr'' lf']
Where: xxxxxxx = Model No.
yyyyy = Software Version
Example: >DEV/RET_K080-4045-I SW_1.02
Equipment Type is a command that retrieves
the model number and software version of the
equipment. The information cannot be
changeds by command.
Содержание KPA-020IN
Страница 2: ......
Страница 13: ...Ku Band Solid State Power Amplifier Revision 0 Preface MN KPA IOM xi NOTES...
Страница 17: ...Ku Band Solid State Power Amplifier Revision 0 Introduction MN KPA IOM 1 4 Figure 1 3 Block Diagram of KPA 040...
Страница 23: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 2 4 Figure 2 1 Redundancy Installation 1...
Страница 31: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 6 NOTES...
Страница 33: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 8 NOTES...
Страница 59: ...Ku Band Solid State Power Amplifier Revision 0 Redundant Configuration MN KPA IOM 5 6 NOTES...
Страница 87: ...Ku Band Solid State Power Amplifier Revision 0 Maintenance and Troubleshooting MN KPA IOM 7 6 NOTES...
Страница 99: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...