Ku-Band Solid-State Power Amplifier
Revision 0
Installation
MN/KPA.IOM
3-3
Table 3-3a. Customer Discrete Control, Connector J5
(Redundant System 1:N )
Pin #
Signal Name
Description
A
Auto Select
Momentary short to pin F to force entire subsystem to
Auto Mode.
B
BU-1 Command
Momentary short to pin F to force backup of KPA #1.
C
Priority 2 Sel
Momentary short to pin F to set KPA #2 as HIGH priority.
D
BU-2 Command
Momentary short to pin F to force backup of KPA #2.
priority.
E
2 Online NO
Open when Omnline, all other conditions tied to pin G.
see Note 1.
F
Remote Common
Control – Remote Common.
G
Online Common
Online Status Common.
H
BU Online NO
Tied to pin G when Redundancy functioning correctly, all
other conditions OPEN. See Note 2.
J
Manual Select
Momentary short to pin F to force entire subsystem to
Manual Mode.
K
1 Online NO
Open when Online, all other conditions tied to Pin G. see
Note 1.
L
2 Fault NO
Open when faulted, else tied to Pin N.
M
Priority 1 SEL
Momentary short to pin F to set KPA #1 as HIGH priority.
N
Fault Common
Fault Status Common.
P
BU Fault NO
Open when faulted, else tied to Pin N.
R
BU Offline CMD
Momentary short to pin F to force backup KPA Offline.
S
1 Fault NO
Open when faulted, else tied to Pin N.
Notes:
1. Online status subject to state of Pin H.
2. When Open, can indicate loss of power or cabling problem. Online State of
unit not determinable when open.
Содержание KPA-020IN
Страница 2: ......
Страница 13: ...Ku Band Solid State Power Amplifier Revision 0 Preface MN KPA IOM xi NOTES...
Страница 17: ...Ku Band Solid State Power Amplifier Revision 0 Introduction MN KPA IOM 1 4 Figure 1 3 Block Diagram of KPA 040...
Страница 23: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 2 4 Figure 2 1 Redundancy Installation 1...
Страница 31: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 6 NOTES...
Страница 33: ...Ku Band Solid State Power Amplifier Revision 0 Installation MN KPA IOM 3 8 NOTES...
Страница 59: ...Ku Band Solid State Power Amplifier Revision 0 Redundant Configuration MN KPA IOM 5 6 NOTES...
Страница 87: ...Ku Band Solid State Power Amplifier Revision 0 Maintenance and Troubleshooting MN KPA IOM 7 6 NOTES...
Страница 99: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...