69
MAkINg CroSSloCk CoNNECtIoNS VIA SwItChboArd
There is no difference in making Switchboard connections via
CrossLock
and non-
CrossLock
methods. If a connection is
attempted via Switchboard, and the following is true:
1
The ACCESS on the far end is running firmware 4.0 or higher
2
The
CrossLock
port is (UDP
9001
) open to the far end
3
Each ACCESS is aware of the other’s Unit ID (Mac address). This is handled behind the scenes in
Switchboard.
Then a
CrossLock
connection will be attempted. If port
9001
is blocked, or if the far end connection has 3.x or lower
firmware, the connection will proceed in the legacy “BRIC Normal” mode.
A successful
CrossLock
connection is indicated by a green “Lock” icon in the lower banner. Because
CrossLock
is
established before an audio stream, and lingers for some time after, this may stay green even when an audio stream is
not active.