measures the Arc On time for each weld. When the
weld cycle is complete the total time for the weld will be
set. (Note 100 = 10.0 sec)
V3
Volts – During the Arc on Time the value represents
the actual arc voltage. The value is in 0.1 volt
increments (100=10.0 volts). When the weld cycle is
complete the value will be the statistical average for the
last weld.
0-102.3
V4
Amps- – During the Arc on Time the value represents
the actual arc current. The value is in 1amp
increments (100=100 amps). When the weld cycle is
complete the value will be the statistical average for the
last weld.
0-1023
V5
Gas Pressure - – During the Arc on Time the value
represents the actual gas pressure. The value is in
1KPa increments (100=100KPa). When the weld
cycle is complete the value will be the statistical
average for the last weld.
0-2032
V6
Wire Speed - – During the Arc on Time the value
represents the actual wire feed speed. The value is in
1-mm/sec increments (100=100 MM/Sec). When the
weld cycle is complete the value will be the statistical
average for the last weld.
0-1000
V7
SEC:MIN – The value is the arc start Second:Minute
based on the Real Time Clock. This value is set when
an arc on condition is detected.
0-65535
V8
HR:DAY - The value is the arc start Hour and Day
based on the Real Time Clock. This value is set when
an arc on condition is detected.
0-65535
V9
MN:YR - The value is the arc start Month and Year
based on the Real Time Clock. This value is set when
an arc on condition is detected.
0-65535
V10
Arc Time Mean - This value is set during the learn
mode for each weld on a part.
0-6553.5
V11
Volt Mean - This value is set during the learn mode for
each weld on a part.
0-102.3
V12
Amp Mean - This value is set during the learn mode for
each weld on a part.
0-600
V13
Gas Pressure Mean - This value is set during the learn
mode for each weld on a part.
0-16.0
V14
Wire Speed Mean - This value is set during the learn
mode for each weld on a part.
0-1000
V15
Spare Register – Not Defined
0-65535
V16
Weld Count – Total number of weld since last reset. If
weld counter reaches the max count of 65535 the
counter will reset to 0.
0-65535
V17
Weld Summary Count – Value indicates the number of
weld summaries stored in memory (Max Count = 500).
0-1365
V18
Sample Count – Value indicates the number of raw
data samples to average to produce a single sample
value as stored in Register 3-5.
0-255
V19
Read Weld Number – the value is used to select the
stored Summary data to be read from memory to
Register 2-12. Range of Value 1-500.
0-1024
V20
Arc On Amps – The value set in this Register is the
0-1023
17
Содержание Micro ADM
Страница 2: ......
Страница 35: ...A 8 NetHub Mounting Dimensions 31...
Страница 42: ...Appendix B Micro ADM Assembly Parts List B 1 Micro ADM Sensor Assembly P N A3A0226 Rev 0 38...
Страница 43: ...39...
Страница 45: ...B 2 Micro ADM Sensor Assembly P N A3A0226 Rev A 41...
Страница 46: ...42...
Страница 48: ...B 3 Micro ADM Sensor Assembly P N A3A0226 Rev B 44...
Страница 49: ...45...
Страница 51: ...B 4 Micro ADM Sensor Assembly P N A3A0226 Rev C 47...
Страница 52: ...48...