5.3 TERMINAL
COMMANDS
The following is a summary of the Terminal Commands supported by the Micro
ADM
:
Command
DESCRITION
RANGE
C0
Voltage zero offset calibration value. (128 = 0 offset)
Negative offset < 128 > Positive offset
0-255
C1
Current zero offset calibration value (128 = 0 offset)
Negative offset < 128 > Positive offset
0-255
C2
Gas Pressure zero offset calibration value (128 = 0
offset)
Negative offset < 128 > Positive offset
0-255
C3
Gas pressure Gain value (Gain = Value/32)
0-255
D
Sets or reads the Real Time Clock date parameters
Format = YY/MM/DD
8 Bytes
T
Sets or Reads the Real Time Clock Time parameters
Format = HH:MM:SS
8 Bytes
M0
ModBus Coils 1-8 Set/Read. Binary Bit’s are set by
decimal value. CR1=1, CR2=2, CR3=4, CR4=8,
CR5=16, CR6=32, CR7=64, CR8=128
0-255
M1
ModBus Coils 9-16 Set/Read. Binary Bit’s are set by
decimal value. CR1=1, CR2=2, CR3=4, CR4=8,
CR5=16, CR6=32, CR7=64, CR8=128
0-255
M2
Baud Rate – Sets the serial communications Baud
Rate 0=38.4Kb, 1=19.2Kb, 2=9600buad, 3=4800 baud
0-3
M3
Sample Count – Number of raw samples to averaged
for a single parameter sample
0-255
M4
Voltage Sigma value. When set to zero parameter
testing is disabled. (Note: Sigma = Value/24)
0-255
M5
Amp Sigma value. When set to zero parameter testing
is disabled. (Note: Sigma = Value/24)
0-255
M6
Gas Sigma value. When set to zero parameter testing
is disabled. (Note: Sigma = Value/24)
0-255
M7
Wire Speed Sigma value. When set to zero parameter
testing is disabled. (Note: Sigma = Value/24)
0-255
M8
Arc Density Sigma value. When set to zero parameter
testing is disabled. (Note: Sigma = Value/24)
0-255
M9
Weld Volume Sigma value. When set to zero
parameter testing is disabled. (Note: Sigma =
Value/24)
0-255
M10
Start/End Test time value. The value specifies the
delay time from Arc On to begin parameter testing and
the time prior to arc off to stop all parameter testing.
0 – 25.5
M11
Number of welds per Part. This value indicates the
number of welds per part as determined by the Learn
mode.
V1
Arc On Status – When the arc is active the value will be
greater 1. When the New Part input is active, the value
will be the calculated End Test time for the current
weld. When the arc is off the value will be 0
0-65535
V2
Arc Time – Weld on timer in 0.1-second intervals.
Value is incremented during a weld cycle. And
0-65535
16
Содержание Micro ADM
Страница 2: ......
Страница 35: ...A 8 NetHub Mounting Dimensions 31...
Страница 42: ...Appendix B Micro ADM Assembly Parts List B 1 Micro ADM Sensor Assembly P N A3A0226 Rev 0 38...
Страница 43: ...39...
Страница 45: ...B 2 Micro ADM Sensor Assembly P N A3A0226 Rev A 41...
Страница 46: ...42...
Страница 48: ...B 3 Micro ADM Sensor Assembly P N A3A0226 Rev B 44...
Страница 49: ...45...
Страница 51: ...B 4 Micro ADM Sensor Assembly P N A3A0226 Rev C 47...
Страница 52: ...48...