when the arc is off.
8
7
Set Clock – When set the Date and Time values set in Register
7 – 12 will be loaded to the Real Time Clock. The Coil will be
reset after the RTC is set. This function will only execute when
the arc is off.
9
8
Learn Mode Enabled – When set the user defined Learn input
is active.
10
9
New Part Enabled – When set the user New Part Input is
active.
11
10
AAD Fault – When set the sensor has detected an
Accumulated Arc Density Fault condition. This output will only
be set when the weld is complete or when the part input is
cleared.
12
11
TIME Fault – When set the sensor has determined an arc time
fault has occurred. If set when the Part input is cleared the
sensor indicates an accumulative arc time fault for the part.
13
12
VOLT Fault – When set the sensor has detected a volt
parameter fault during the previous weld. If set when the Part
input is cleared it indicates an arc density fault has occurred.
14
13
AMP Fault – When set the sensor has detected an amp
parameter fault during the previous weld. If set when the Part
input is cleared it indicates an arc density fault has occurred.
15
14
GAS Fault – When set the sensor has detected a gas pressure
fault during the previous weld.
16
15
WIRE Fault - When set the sensor has detected a wire speed
parameter fault during the previous weld. If set when the Part
input is cleared it indicates a total volume applied fault has
occurred.
The following is the Register definitions address 0-26:
REGISTER
ADDRESS
DESCRIPTION
1
0
Arc On Status – When the arc is active the value will be
greater then 1. When the arc is off the value will be 0
2
1
Arc Time – Weld on timer in 0.1-second intervals. Value is
incremented during a weld cycle and measures the Arc On
time for each weld. When the weld cycle is complete the
total time for the weld will be set. (Note 100 = 10.0 sec)
3
2
Volts – During the Arc on Time the value represents the
actual arc voltage. The value is in 0.1-volt increments
(100=10.0 volts). When the weld cycle is complete the
value will be the statistical average for the last weld.
4
3
Amps- – During the Arc on Time the value represents the
actual arc current. The value is in 1amp increments
(100=100 amps). When the weld cycle is complete the
value will be the statistical average for the last weld.
5
4
Gas Pressure - – During the Arc on Time the value
represents the actual gas pressure. The value is in 0.1 PSI
or 1KPa increments (100=100Kpa/10.0 PSI). When the
weld cycle is complete the value will be the statistical
average for the last weld.
6
5
Wire Speed - – During the Arc on Time the value
represents the actual wire feed speed. The value is in 1-
9
Содержание Micro ADM
Страница 2: ......
Страница 35: ...A 8 NetHub Mounting Dimensions 31...
Страница 42: ...Appendix B Micro ADM Assembly Parts List B 1 Micro ADM Sensor Assembly P N A3A0226 Rev 0 38...
Страница 43: ...39...
Страница 45: ...B 2 Micro ADM Sensor Assembly P N A3A0226 Rev A 41...
Страница 46: ...42...
Страница 48: ...B 3 Micro ADM Sensor Assembly P N A3A0226 Rev B 44...
Страница 49: ...45...
Страница 51: ...B 4 Micro ADM Sensor Assembly P N A3A0226 Rev C 47...
Страница 52: ...48...