mm/sec increments (100=100 MM/Sec/100 IPM). When
the weld cycle is complete the value will be the statistical
average for the last weld.
7
6
RTC BCD SEC:MIN – The value is the arc start SEC:MIN
based on the Real Time Clock. This value is set when an
arc on condition is detected. (MSB = seconds; LSB =
Minutes)
8
7
RTC BCD HR:DAY - The value is the arc start Hour and
Day based on the Real Time Clock. This value is set when
an arc on condition is detected. (MSB = Hour; LSB = Day)
9
8
RTC BCD MN:YR - The value is the arc start Month and
Year based on the Real Time Clock. This value is set when
an arc on condition is detected. (MSB = Month; LSB =
Year)
10
9
Arc Time Mean – Arc Time mean value for in-process limits
11
10
Arc Voltage Mean – Voltage mean value used for in-
process limits.
12
11
Arc Current Mean – Amperage mean value used for in-
process limits.
13
12
Gas Pressure Mean – Gas pressure mean value used for
in-process limits.
14
13
Wire Speed Mean – Wire speed mean value used for in-
process limits.
15
14
Spare – Not Used
16
15
Weld Count – Total number of weld since last reset. If weld
counter reaches the max count of 65535 the counter will
reset to 0.
17
16
Weld Summary Count – Value indicates the number of weld
summaries stored in memory (Max Count = 500).
18
17
Part Fault Counter – Total number of faulted parts since last
fault count reset.
19
18
Read Weld Number – the value is used to select the stored
Summary data to be read from memory to Register 2-12.
Range of Value 1-500.
20
10
Arc On Amps – The value set in this Register is the welding
current that must be exceeded to establish an arc on
condition. Value is in 1-amp increments (10 = 10 amps).
21
20
Arc On Volts – The value set in this Register is the welding
voltage that must be exceeded to establish an arc on
condition. Value is in 0.1-volt increments (100 =10.0 volts).
22
21
SAMPLE COUNT: TIME Sigma – The MSB byte indicates
the number of raw data samples to average to produce a
single sample value as stored in Register 3-5. The LSB
byte sets the Arc Time sigma value used by sensor for
process limits Setting the Sigma value to 0 will disable the
test function. (Arc Time Sigma = LSB/24; i.e. 55 =2.29)
23
22
VOLT: AMP Sigma – The MSB byte sets the Voltage sigma
value used by the sensor for process limits. The LSB byte
sets the Amp sigma value used by sensor for process limits
Setting the Sigma value to 0 will disable the test function.
(Sigma = MSB, LSB/24; i.e. 55 =2.29)
24
23
GAS: WIRE Sigma – The MSB byte sets the Gas Pressure
sigma value used by the sensor for process limits. The
LSB byte sets the Wire Speed sigma value used by sensor
for process limits. Setting the Sigma value to 0 will disable
10
Содержание Micro ADM
Страница 2: ......
Страница 35: ...A 8 NetHub Mounting Dimensions 31...
Страница 42: ...Appendix B Micro ADM Assembly Parts List B 1 Micro ADM Sensor Assembly P N A3A0226 Rev 0 38...
Страница 43: ...39...
Страница 45: ...B 2 Micro ADM Sensor Assembly P N A3A0226 Rev A 41...
Страница 46: ...42...
Страница 48: ...B 3 Micro ADM Sensor Assembly P N A3A0226 Rev B 44...
Страница 49: ...45...
Страница 51: ...B 4 Micro ADM Sensor Assembly P N A3A0226 Rev C 47...
Страница 52: ...48...