5-16
DTMF Programming Commands
ENTRY DESCRIPTION
DEFAULT
*10XX READ SCHEDULER EVENT TIME (30-49)
*11XX PROGRAM SCHEDULER EVENT TIME (30-49)
*12XX ERASE SCHEDULER EVENT TIME (30-49)
*13XX READ USER MACRO COMMAND (01-40)
*14XX PROGRAM USER MACRO COMMAND (01-40)
*15XX ERASE USER MACRO COMMAND (01-40)
*16XX READ EVENT MACRO COMMAND (01-50)
*17XX PROGRAM EVENT MACRO COMMAND (01-50)
*18XX ERASE EVENT MACRO COMMAND (01-50)
*20
SEND TIME OF DAY
*21
PROGRAM CLOCK LONG TIME OF DAY (All Clock Parameters Including Year)
*22
PROGRAM CLOCK SHORT TIME OF DAY (Hours and Minutes only)
*29
READ FORCED ENTRY KEY
*29X
PROGRAM FORCED ENTRY KEY
D
*30XX PLAY VOICE MESSAGE (1-20)
*31XX PROGRAM VOICE MESSAGE (1-20)
*32XX ERASE VOICE MESSAGE (1-20)
*33
SEND CW IDENTIFICATION
*34
PROGRAM CW IDENTIFICATION
*35
ERASE CW IDENTIFICATION
*36XX SET CW TONE FREQUENCY (01-32)
25
*37X
SET CW SPEED (1-5) (1=10 2=15 3=20 4=25 5=30WPM)
3
*38XX SET MUTING TONE FREQUENCY (01 – 32)
20
*501* PROGRAM CONTROL OPERATOR NUMBER PORT #1 (REPEATER)
100
*502* PROGRAM CONTROL OPERATOR NUMBER PORT #2 (LINK)
200
*503* PROGRAM DTMF ACCESS NUMBER
325
*504* PROGRAM DTMF PAD TEST NUMBER
375
*505* PORT #2 DISCONNECT CODE
5000
*506* PORT #2 CONNECT CODE
5001
*507* PORT #2 RECEIVE ONLY CODE
5002
*508* PLAY VOICE MESSAGE DEMO CODE
700
Содержание CAT-250
Страница 49: ...9 1 Chapter 9 Drawings CAT 250 Repeater Controller Figure 9 1 ...
Страница 51: ...10 2 ...
Страница 52: ...10 3 ...
Страница 53: ...10 1 ...