CompuSTAR Firstech CM800-S Скачать руководство пользователя страница 17

 

17 

 Option Programming 

 

How to Program Options 

There are two ways to set options on the CM8 control modules. You can use the FT-OP500-KIT or most 
Firstech remotes. The remotes include 4 or 5 button 1 and 2 Way remotes.

 

 

Option Programming Using the FT-OP500-KIT 

The OP500 can be used to change anything in the Option Tables. It is required to change settings in the 
Special Option Group. 
 

STEP 1:

 

Make sure system is unlocked/disarmed. 

Connect the antenna cable to the 4 or 6 pin port on 

the top of the OP500. Once connected, the OP500 will power up as long as CN1 on the control module is 
connected properly. 
 

STEP 2: 

Use the left or right arrow keys on the OP500 to select option. Use the up or down arrow 

buttons to select the option setting. “1” is the default setting, “2”, “3”, and “4” are the optional settings. 
 
Special Option Group 1: Change the timed output of Auxiliary 1 and 2. 
 

STEP 3:

 

Hold the “W” (Write) button for 3 seconds. This finalize option changes to the control module. 

Wait until OP500 displays “Success” before disconnecting. 
 
To reset the options, hold the “R” (Reset) button and “W” (Write) buttons for 3 seconds. Then hold the 
“W” button for 3 seconds.   
 

Option Programming Using Compatible Remotes 

Using a remote is a timed process so review this section before beginning. Options cannot be 
programmed with 1 button remotes. 

IMPORTANT: 

Special Option Groups cannot be programmed with 

remotes 

– OP500 must be used. 

 

STEP 1:

 Select the option you wish to program. Use the correct remote table below: 

 

How to Program Options With 2 Way Remotes with Separate Lock and Unlock Buttons 

 

Wai

fo

ch

irp

 

be

tw

ee

n

 ea

ch

 

tap

 

S

croll

 Th

roug

h

 

M

en

(Wa

it

 f

or

 

fl

as

h

 be

tw

ee

ea

ch

 t

ap

Wai

fo

co

rr

es

po

nd

ing

 

pa

rki

ng

 l

igh

fl

as

h

 an

d/or

 

sir

en

 ch

irp

 

be

fore se

lec

ti

ng

 

op

ti

on

 

S

elect

 O

p

ti

on

 1

 

S

elec

O

p

ti

on

 2

 

S

elect

 O

p

ti

on

 3

 

Содержание Firstech CM800-S

Страница 1: ...rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device may accept any interference received including interference that may cause undesir...

Страница 2: ...ng on Option 2 04 6 Alternator Sensing Option 2 04 Setting 3 7 Assumed Timed Crank Option 2 04 Setting 4 7 Diesel Timer 8 CM800 S Firmware 8 CM800 S Wiring Schematic Remote Start 9 Option Programming...

Страница 3: ...eek professional installation Call 888 820 3690 or visit our website at www compustar com to locate your nearest dealer Caution The Manufacturer s warranty will be void if this product is installed by...

Страница 4: ...the system into Valet using the remote you must turn the ignition on and then tap the Lock and Trunk buttons System comes in Tachless Sensing Mode The CM800 S comes preprogrammed in No Tach Sensing Mo...

Страница 5: ...ghts will flash once confirming each additional remote The CM800 S can store up to three remotes Exiting Programming Programming is a timed sequence The parking lights will flash twice signaling the e...

Страница 6: ...wire on Connector 1 This wire is powered by an internal relay in the control module In the default position the jumper is set to 2nd Ignition 2nd Ignition is common on GM and Toyota vehicles and will...

Страница 7: ...Turn the ignition to the run position The stator wire should now test between 1 6V DC C Start the vehicle with the key The stator wire should now test between 12 14V DC at idle STEP 3 Process complet...

Страница 8: ...sel Timer to allow the vehicle s glow plug wire to heat up There are two time settings on this unit 7 or 18 seconds This will allow the ignition to power up and then crank once the time has expired an...

Страница 9: ...9 CM800 S Wiring Schematic Remote Start...

Страница 10: ...during remote start The behavior of this wire is selectable by a jumper inside the control module By default this wire powers up as a 2nd Ignition trigger It is changeable to a 2nd Starter or 2nd Acc...

Страница 11: ...This wire can also be programmed through the Option 3 11 It can be change to Ignition Auxiliary 1 or Auxiliary 2 output Pin 8 Gray Black Hood Pin negative input This input is a safety shut down and al...

Страница 12: ...verse polarity for trigger door lock systems Pin 5 Blue Black Lock 250mA negative output This is an optional output that will provide a pulse for locking doors System will lock doors IMPORTANT You mus...

Страница 13: ...Pulse Single Pulse Off Feature Default Setting I Optional Setting II Optional Setting III Optional Setting IV 2 01 Timer Start or Minimum interval between cold Start 3 Hour 1 5 Hour 2 02 Minimum Cran...

Страница 14: ...the option description below Option Menu Descriptions 1 01 Unlock Before Lock After Starting If enabled this option will unlock the doors before remote starting start the vehicle then lock the doors a...

Страница 15: ...control module will remote start Default 1 Will start every 3 hours until the vehicle is remote started or started by key and run for the set run time in option 1 08 Option 2 Will start every 1 5 hour...

Страница 16: ...llows the output duration to be set for a specific length of time 3 03 Aux 2 Output This option determines the duration of the Aux 2 output Setting 4 allows the output duration to be set for a specifi...

Страница 17: ...l settings Special Option Group 1 Change the timed output of Auxiliary 1 and 2 STEP 3 Hold the W Write button for 3 seconds This finalize option changes to the control module Wait until OP500 displays...

Страница 18: ...Tap Key Button Option Menu 2 Lock Unlock for 3 seconds then Lock Key for 3 seconds Hold Trunk Key for 3 seconds Tap Lock Button Tap Unlock Button Tap Key Button Option Menu 3 Lock Key for 3 seconds t...

Страница 19: ...signed to only work with 4 Pin antennas and compatible remotes It does not work with 6 to 6 Pin antennas I am trying to program options with the OP500 Option Programmer and it flashes ER 01 when I plu...

Страница 20: ...using a coil change to an injector or try alternator mode If you are using the tachless sensing mode and it does not start check the two power wire on the control module If it does not remote start y...

Страница 21: ...am 5 00 pm Pacific Standard Time Email support compustar com Web techfeed compustar com Wiring Diagrams Go to www firstechonline com to access Computech3 If you are an authorized dealer and unable to...