Option Programming Tables 

 

 

 

Feature 

Default Setting - I 

Optional 

Setting - II 

Optional 

Setting - III 

Optional 

Setting - IV 

1-01 

Unlock Before, Lock After 

Starting 

OFF 

ON 

Lock After Start 

Only 

Lock After 

Shutdown Only 

1-02 

Lock / Unlock Pulse 

Duration 

0.8 sec 

2.5 sec 

0.125 sec 

3.5 sec 

1-03 

Double Pulse Locks 

Off 

Unlock 

Lock 

Both 

1-04 

Driver's Priority Unlock 

OFF 

ON 

  

  

1-05 

Double Pulse Disarm 

Standard 

Double Pulse 

  

  

1-06 

Ign + Acc Pulse With 

Disarm 

OFF 

ON 

  

  

1-07 

Remote Start Runtime 

15 min 

25 min 

45 min 

3 min 

1-08 

Auto Rearm 

OFF 

30 sec 

60 sec 

5 min 

1-09 

Trunk Output Timing 

1 sec 

0.5 sec 

2 sec 

  

1-10 

Unlock/Disarm With Trunk 

Release 

Unlock, Factory 

Disarm, and Trunk 

Release 

Factory Disarm, 

Trunk Release Only 

Trunk Release Only 

  

1-11 

Trigger Start 

Triple Pulse 

Double Pulse 

Single Pulse 

 Off 

 

 

 

 

 

 

 

  

Feature 

Default Setting - I 

Optional 

Setting - II 

Optional 

Setting - III 

Optional 

Setting - IV 

2-01 

Timer Start or Minimum 

interval  

between cold Start 

3 Hour 

1.5 Hour 

  

  

2-02 

Minimum Crank Time With 

Tachless Sensing 

0.8 or 1.0 sec  

by Option 2-05 

+0.6 sec To Crank 

Time 

  

  

2-03 

Ignition Controlled Door 

Locks 

OFF 

ON 

Ignition Lock Only 

Ignition Unlock Only 

2-04 

Engine Sensing 

Tachless 

Tach 

Alternator 

3.0 sec Crank 

2-05 

Minimum Crank Time 

Standard 

+0.2 sec To Crank 

Time 

-0.2 sec To Crank 

Time 

  

2-06 

Diesel Timer 

Off 

7 sec 

18 sec 

Delayed Ignition 

(GM) 

2-07 

Rearm Output 

1st Lock, After 

Start, After 

Shutdown 

1st Lock, Shutdown 

After Start Only 

After Shutdown 

Only 

2-08 

Horn Output 

On Double Lock 

On Lock and Unlock 

On Lock, Unlock, 

and Start 

Panic Only 

2-09 

Horn Honk 

Pulsed 

Latched 

  

  

2-10 

Advanced Tachless 

OFF 

ON 

  

  

 

 

Feature 

Default Setting - I 

Optional 

Setting - II 

Optional 

Setting - III 

Optional 

Setting - IV 

3-01 

Secure Auxiliary Output 

ON 

OFF 

On While Armed 

  

Содержание Firstech CM800-S

Страница 1: ...rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device may accept any interference received including interference that may cause undesir...

Страница 2: ...ng on Option 2 04 6 Alternator Sensing Option 2 04 Setting 3 7 Assumed Timed Crank Option 2 04 Setting 4 7 Diesel Timer 8 CM800 S Firmware 8 CM800 S Wiring Schematic Remote Start 9 Option Programming...

Страница 3: ...eek professional installation Call 888 820 3690 or visit our website at www compustar com to locate your nearest dealer Caution The Manufacturer s warranty will be void if this product is installed by...

Страница 4: ...the system into Valet using the remote you must turn the ignition on and then tap the Lock and Trunk buttons System comes in Tachless Sensing Mode The CM800 S comes preprogrammed in No Tach Sensing Mo...

Страница 5: ...ghts will flash once confirming each additional remote The CM800 S can store up to three remotes Exiting Programming Programming is a timed sequence The parking lights will flash twice signaling the e...

Страница 6: ...wire on Connector 1 This wire is powered by an internal relay in the control module In the default position the jumper is set to 2nd Ignition 2nd Ignition is common on GM and Toyota vehicles and will...

Страница 7: ...Turn the ignition to the run position The stator wire should now test between 1 6V DC C Start the vehicle with the key The stator wire should now test between 12 14V DC at idle STEP 3 Process complet...

Страница 8: ...sel Timer to allow the vehicle s glow plug wire to heat up There are two time settings on this unit 7 or 18 seconds This will allow the ignition to power up and then crank once the time has expired an...

Страница 9: ...9 CM800 S Wiring Schematic Remote Start...

Страница 10: ...during remote start The behavior of this wire is selectable by a jumper inside the control module By default this wire powers up as a 2nd Ignition trigger It is changeable to a 2nd Starter or 2nd Acc...

Страница 11: ...This wire can also be programmed through the Option 3 11 It can be change to Ignition Auxiliary 1 or Auxiliary 2 output Pin 8 Gray Black Hood Pin negative input This input is a safety shut down and al...

Страница 12: ...verse polarity for trigger door lock systems Pin 5 Blue Black Lock 250mA negative output This is an optional output that will provide a pulse for locking doors System will lock doors IMPORTANT You mus...

Страница 13: ...Pulse Single Pulse Off Feature Default Setting I Optional Setting II Optional Setting III Optional Setting IV 2 01 Timer Start or Minimum interval between cold Start 3 Hour 1 5 Hour 2 02 Minimum Cran...

Страница 14: ...the option description below Option Menu Descriptions 1 01 Unlock Before Lock After Starting If enabled this option will unlock the doors before remote starting start the vehicle then lock the doors a...

Страница 15: ...control module will remote start Default 1 Will start every 3 hours until the vehicle is remote started or started by key and run for the set run time in option 1 08 Option 2 Will start every 1 5 hour...

Страница 16: ...llows the output duration to be set for a specific length of time 3 03 Aux 2 Output This option determines the duration of the Aux 2 output Setting 4 allows the output duration to be set for a specifi...

Страница 17: ...l settings Special Option Group 1 Change the timed output of Auxiliary 1 and 2 STEP 3 Hold the W Write button for 3 seconds This finalize option changes to the control module Wait until OP500 displays...

Страница 18: ...Tap Key Button Option Menu 2 Lock Unlock for 3 seconds then Lock Key for 3 seconds Hold Trunk Key for 3 seconds Tap Lock Button Tap Unlock Button Tap Key Button Option Menu 3 Lock Key for 3 seconds t...

Страница 19: ...signed to only work with 4 Pin antennas and compatible remotes It does not work with 6 to 6 Pin antennas I am trying to program options with the OP500 Option Programmer and it flashes ER 01 when I plu...

Страница 20: ...using a coil change to an injector or try alternator mode If you are using the tachless sensing mode and it does not start check the two power wire on the control module If it does not remote start y...

Страница 21: ...am 5 00 pm Pacific Standard Time Email support compustar com Web techfeed compustar com Wiring Diagrams Go to www firstechonline com to access Computech3 If you are an authorized dealer and unable to...

Отзывы: