16
2-05
Minimum Crank Time
- This feature applies to feature 2-02. It will add or remove crank time to
the default setting of the afore mentioned option.
2-06
Diesel Timer
– Use this option if you can’t find the glow plug wire. You can use setting 2 for a
default wait-to-crank; otherwise, you can adjust the time with your OP-500 Programmer.
2-07
Rearm Output
– This option changes the events when the orange rearm output will pulse from
the control module. In the default mode the wire will pulse every time you lock, after remote start
confirmation, and remote start shutdown. Setting 2 only pulses the wire upon lock and remote
start shutdown. Setting 3 pulses the wire upon after remote start only. Setting 4 pulses the wire
upon remote start shutdown only. Optional event to prevent factory alarm from triggering.
2-08
Horn Output
– This feature changes when the white wire on CN2 will send a pulses.
2-09
Horn Honk
-
This feature will change the behavior of horn output (white wire CN2).
2-10
Advanced Tachless
-
This feature will provide an enhanced Tachless engine sensing mode.
3-01
Secure Auxiliary Output
-
This feature, in the default option should help prevent accidental
activation of the AUX outputs. 1 Way remotes require the user to hold trunk+start buttons for 2.5
seconds before activating AUX outputs Option setting II turns this feature off.)
3-02
Aux 1 Output
- This option determines the duration of the Aux 1 output. Setting 4 allows the
output duration to be set for a specific length of time.
3-03
Aux 2 Output
- This option determines the duration of the Aux 2 output. Setting 4 allows the
output duration to be set for a specific length of time.
3-04
Aux 1 Output Control
– This option sets the condition which controls Auxiliary 1 and how it is
triggered. Please see the option table 3 for details.
3-05
Aux 2 Output Control
- This option sets the condition which controls Auxiliary 2 and how it is
triggered. Please see the option table 3 for details.
3-06
Horn Mute Control On Remote
– Enabling this option will allow the user to change the horn
mute on or off using their remote.
3-07
Sliding Door (Aux 1, Aux 2) Control for iDatalink Modules
– This option changes the activity
of auxiliary 1 and 2 through iDatalink bypass modules only.
3-08
Connector 2, Pin 4
- This option will change the behavior of the black wire on Connector 2
(CN2). At default the wire will act as a status output but can be changed to (-) ignition, auxiliary 1
or auxiliary 2.
3-09
Connector 2, Pin 5
- This option will change the behavior of the orange wire on Connector 2
(CN2). At default the wire will act as a rearm output but can be changed to (-) ignition, auxiliary 1
or auxiliary 2.
3-10
Connector 2, Pin 6
- This option will change the behavior of the orange/white wire on Connector
2 (CN2). At default the wire will act as a disarm output but can be changed to (-) ignition, auxiliary
1 or auxiliary 2.
3-11
Connector 2, Pin 7
- This option will change the behavior of the white wire on Connector 2
(CN2). At default the wire will act as a horn output but can be changed to (-) ignition, auxiliary 1 or
auxiliary 2.
Содержание Firstech CM800-S
Страница 9: ...9 CM800 S Wiring Schematic Remote Start...